EZ-Manager Wizard (Cont.)

(Continued from previous page)

IP Configuration

a)In the Media Type field, use the Left/Right arrow keys to select IP.

Note: By default, the Pro:Centric Manual Configuration screen initially shows RF configuration fields. When you select “IP” as the Media Type, the Data Channel and

Signal Strength fields are replaced with (IP) Address and Port fields.

b)In the Address and Port fields, either key in or use the

Left/Right arrow keys to select the appropriate values for the Pro:Centric server IP address and port number.

The IP address must match the IPv4 multicast address and the port number must match the port number that is set in the Pro:Centric server.

4.Once all fields are completed as required, you have two options (see also note below):

• To save the data entered and exit the wizard, use the arrow keys to select Exit and then press OK. In the subsequent pop-up confirmation window, select Save and Exit, and then press OK once more. The Pro:Centric application and/or E-Z Installation data will be downloaded to the STB at a later time. This option is useful, in particular, if the Pro:Centric server has not yet been configured.

• To initiate a real-time download of Pro:Centric application and/or E-Z Installation data, use the arrow keys to select Next, and then press OK.

The EZ-Manager Wizard will proceed with the remaining Pro:Centric application and/or E-Z Installation data download steps, as shown on the Processing the Pro:Centric Configuration screen.

Note: With RF configuration, Pro:Centric server data must be present on the RF channel selected as the STB’s Data Channel in order for you to select “Next” (you will see a “Data Channel found” message below the signal strength indicator). With IP configuration, Pro:Centric server data must be present via the wired LAN cable connection in order for you to select “Next” (you will see an “IP server found” message below the Port field).

When the Pro:Centric configuration is complete, an EZ-Manager Configuration Complete screen is displayed, and after 10 seconds, the wizard exits, and the STB turns OFF.

Note: With the EZ-Manager Configuration Complete screen on display, you also have the option to manually turn off or reboot the STB. If desired, select Turn Off or Reboot, respectively, and then press OK on the Installer Remote.

EZ-Manager Wizard

1 2 3 4

Pro:Centric Manual Configuration

Pro:Centric Mode

 

GEM

 

 

Media Type

<

 

IP

>

 

Addresss

 

255

255

 

255

255

 

 

 

 

 

 

 

 

 

 

 

 

Port

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Back

 

 

 

Exit

 

 

 

 

Next

 

 

 

 

 

 

 

 

 

 

 

Pro:Centric Manual Configuration Screen with

IP Media Fields

EZ-Manager Wizard

1 2 3 4

Pro:Centric Manual Configuration

!

Are you sure you want to exit the wizard?

>

 

Pro:Centric ModeIf you select ‘OK’<now, your settingsGEMwill be lost

 

 

 

and you will exit

the setup wizard.

 

 

 

Channel Number

 

 

 

1

 

 

 

 

Signal Strength

 

 

 

 

 

0%

 

 

This window will close and you will be returned to

 

 

 

 

 

 

 

the previous page automatically in 2 seconds.

 

 

 

0%

Signal Quality

 

 

 

 

 

 

 

 

 

Save and Exit

 

 

OK

No

 

Cancel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Back

 

 

 

Exit

 

 

 

 

Next

 

 

 

 

 

 

 

 

 

 

 

 

 

EZ-Manager Wizard

1 2 3 4

Processing the Pro:Centric Configuration...

Downloading the Pro:Centric application files takes a few minutes.

Please wait...

1%

 

Retrieving files from data channel 75

Application files

In progress...

Maintenance files

Pending...

Warning - Do not remove AC power or the signal cables during these steps

EZ-Manager Wizard

1 2 3 4

EZ-Manager Configuration Complete

The TV will turn off in

3 second(s).

Installed Components

Pro:Centric Application

GEM application downloaded

Maintenance Files

STB-2000_Config.tlx

Reboot

 

Turn Off

 

 

 

206-4256