5
2 SeT-UP
Read the Activate Cardio Series Operation Manual before setting up the Life Fitness product. Contact Life Fitness Cus-
tomer Support Services to request a printed copy of the Activate Cardio Series Operation Manual.
Follow all safety instructions. Place the product where it will be used before beginning the set-up procedure.
eLeCTRICAL POWeR ReqUIRemeNTS
The Life Fitness Treadmill requires a dedicated* line with isolated neutral according to the electrical configurations listed
in the chart below.
* One individual branch circuit for each treadmill per NEC article 210-21 (b) (1) and 210-23 (or other appropriate, country specific electrical compliance
guidelines). The hot and neutral wires must each be routed independently (not looped or tied to other circuits).
note: Do not modify the plug provided with this product. If the plug does not fit into an available electrical outlet, have a
proper outlet installed by a qualified electrician.
GROUNDING INSTRUCTIONS
This Life Fitness product must be properly grounded. If the unit malfunctions or breaks down, proper grounding provides
a path of least resistance for the electric current, which reduces the risk of shock to anyone touching or using the equip-
ment. Each unit is equipped with an electrical cord, which includes an equipment grounding conductor and a grounding
plug. The plug must be inserted into an outlet that has been properly installed and grounded in accordance with all local
codes and ordinances.
A temporary adapter mUST NOT Be USeD to connect this plug to a two-pole receptacle in North
America. If a properly grounded, 20-amp outlet is not available, one must be installed by a qualified
electrician. models drawing 16 amps or more must be installed on a dedicated line.
DANGeR: A risk of electrical shock may result from improper connection of the equipment-grounding
conductor. Check with a qualified electrician if in doubt as to proper grounding technique. DO NOT
modify the plug provided with the product. If it will not fit an electrical outlet, have a proper outlet
installed by a qualified electrician. Any modification to the electrical plug will result in a voided warranty.