Lifebreath 155MAX, 200MAX, 95MAX installation manual Balancing Collar Instructions, 1/2”

Models: 155MAX 95MAX 200MAX

1 32
Download 32 pages 15.63 Kb
Page 26
Image 26
BALANCING COLLAR INSTRUCTIONS

BALANCING COLLAR INSTRUCTIONS

Push and turn with slotted screwdriver. Damper automatically locks when pressure is released.

Hard/Rigid

1/2” ducting

When connecting ductwork to the collar, take note where screws are located. Screws should be located no further than 1/2” from outside edge of collar, so as not to impede operation of the damper.

1/2”

Insulated flexible

ducting

Installations where the HRV is ducted directly to the return of a furnace may require additional dampening on the fresh air to building duct. This is due to the high return static pressures found in some furnace installations.

26