Lifebreath AH40DHW, AH60DHW, AH40BHW, AH80BHW, AH60BHW Optional Dehumidistat, 99-130W

Models: AH60BHW AH80BHW AH40BHW AH40DHW AH60DHW

1 32
Download 32 pages 22.01 Kb
Page 20
Image 20
Optional Dehumidistat

Optional Dehumidistat

Dehumidistat to

Setting

Relative

 

 

Conditions

Outside

 

 

 

 

 

 

 

 

 

 

 

TER:

 

 

t

 

 

WIN

 

 

 

 

 

Set deh

umidista

 

.

 

 

to

40%

 

een

30%

 

betw

 

 

too dry,

 

If

home is

 

 

setting.

adjust to higher

 

 

id,

If home

is too hum

 

lower sett

ing.

adjust to

 

 

 

 

 

 

 

 

 

 

 

SUMMER

:

tat

 

 

 

 

 

 

umidis

 

 

 

Set deh

 

 

.

 

 

 

 

 

to OFF

 

 

 

 

 

An optional dehumidistat can be connected to the furnace to help eliminate excessive moisture during the heating season. When the dehumidistat senses moisture in excess of the control setpoint, the blower will be overridden into high speed. This will increase the ventilation airflow and create a dehumidification affect. Typical settings are between 30-40 during the winter and OFF for all other seasons.

The dehumidistat will connect to R&G terminals on the furnace.

Part # 99-130W

Note: Do not use dehumidistat for hot southern climates.

When using a Dehumidistat or Interface Relay to initiate high speed blower operation on a furnace, certain thermostats will initiate the outdoor cooling condenser when R and G are closed.

Use this wiring configuration to stop the Dehumidistat from initializing the condenser unit. This problem can occur at the thermostat because the Y terminal is connected to the G terminal internal to the stat. When R and G are closed at the furnace (by dehumidistat or relay) 24 Volts is sent to G at thermostat. 24 Volts is then sent through Y which will initiate outdoor condenser. The relay will isolate this problem.

NOTE: This problem does not occur with all thermostats, therefore it is important to fully commission the installation to determine if this relay configuration is required.

Interface Relay or Dehumidistat

24 Volt

Relay

R G W Y C

NO

COM

NC

R G W Y

T-stat

Furnace

TB-102

 

1099

20

Page 20
Image 20