READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE.
This fixture is intended for installation in accordance with the National Electrical Code and local or Federal code specifications. To assure full compliance with codes and regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
INSTRUCTION SHEET NO.
IS:1100F
D0605 | Page 1 of 2 |
Installation of Lytecaster® Frame-in-Kit 1100F Series
WARNING – (RISK OF FIRE) Do not install insulation within 3 inches of fixture sides or wiring
compartments, nor above fixture in such a manner as to entrap heat.
Fig. A | Fig. B |
1. | 2. |
Fig. C | Fig. D |
3. | 4. |
NEW CONSTRUCTION
1. |
WOOD JOIST/METAL STUD CONSTRUCTION (FIG. E): Line up bot- |
tom edge of ADJUSTABLE MOUNTING BAR with bottom of wood joist. |
Fasten MOUNTING FRAME to wood joist by nailing MOUNTING BAR |
TAB or nail into joist. |
SUSPENDED GRID CEILING (FIG. G): |
Position notched area of ADJUSTABLE MOUNTING BARS on top of T- |
BAR for proper spacing to finished ceiling. Lock MOUNTING BARS by |
bending TAB underneath |
use screws to lock MOUNTING BARS (Fig. G2). |
WIRE TO SUPPLY LEADS: |
For cable, use |
ADJUSTABLE
MOUNTING BARS
LOCKING SCREW
LINE UP BOTTOM
EDGE WITH BOTTOM
OF WOOD JOIST
Fig. E
MOUNTING FRAME
CENTERING SLOTS
leads to neutral (white) supply leads. Black fixture leads to hot (black) |
supply leads. Bare fixture wire to supply ground. Use wirenuts (local |
hardware item). Place all electrical connections in the |
Box cover. |
NOTE: ADJUSTABLE MOUNTING BARS are
MOUNTING BARS can be extended to 24”. The MOUNTING FRAME can be mounted
For suspended ceilings, make certain that bottom of MOUNTING FRAME is no higher than 1” above finished ceiling (Fig. G).
2. |
Install plasterboard or other dry type ceiling. Hole in board can be cut |
either on floor or after the board is secured in the ceiling. Use MOUNT- |
ADJUSTABLE MOUNTING BARS | MOUNTING FRAME |
| (NARROW SIDE) |
LINE UP BOTTOM EDGE WITH
BOTTOM OF WOOD JOIST
Fig. F
ING FRAME opening as cutting guide template for hole – make sure |
ROTO CLIPS are rotated out of hole area. |
NOTE: For wet plaster ceiling, use Plaster Ring Accessory No. 1961 - order separately.
3. |
| See separate instruction sheet |
4. |
| for your choice of reflector trim. |
U.S. Patent Nos. 5,045,985; 4,313,154; 4,327,403
ADJUSTABLE MOUNTING BARS
Fig. G
G1G2
1" MAX
®LIGHTOLIER a GENLYTE company. 631 Airport Road, Fall River, MA 02720