| Specification Decorative Performance Pendalyte 412U |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
Page 4 of 6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 12" Compact Fluorescent |
Satin Aluminum Reflector Catalog No. 41257U / 42SR, 57W CFL, 4300 Lumens.
625
60°
1250
1875 |
|
2500 | 30° |
|
Report No. 2592FR
SC = .7
CANDLEPOWERSUMMARY | ZONAL LUMENS AND PERCENTAGES | |||||
ANGLE | MEANCP | LMS | ZONE | LUMENS | % LAMP | %LUMINAIRE |
0 | 2414 |
| 1305 | 30.37 | 52.46 | |
5 | 2354 | 220 | 1885 | 43.84 | 75.73 | |
10 | 2076 |
| 2453 | 57.05 | 98.55 | |
15 | 1746 | 498 | 2489 | 57.89 | 100.00 | |
20 | 1459 |
| 604 | 14.05 | 24.27 | |
25 | 1261 | 588 | 36 | .84 | 1.45 | |
30 | 1104 |
| 0 | .00 | .00 | |
35 | 928 | 579 | 2489 | 57.89 | 100.00 | |
40 | 730 |
|
| ** EFFICIENCY = 57.9% ** | ||
45 | 534 | 412 |
| |||
50 | 328 |
|
|
|
|
|
55 | 156 | 157 |
|
|
|
|
60 | 58 |
|
|
|
|
|
65 | 26 | 31 |
|
|
|
|
70 | 12 |
|
|
|
|
|
75 | 4 | 5 |
|
|
|
|
80 | 0 |
|
|
|
|
|
85 | 0 | 0 |
|
|
|
|
90 | 0 |
|
|
|
|
|
|
|
|
|
| COEFFICIENTS OF UTILIZATION |
|
|
|
| |||||||||
Ceiling |
|
| 80% |
| 70% |
| 50% |
|
| 30% |
|
| ||||||
|
|
|
|
|
|
| ||||||||||||
| Wall | 70 | 50 | 30 | 10 | 50 | 10 |
| 50 | 10 |
|
| 50 | 10 | 0 |
| ||
| RCR |
| Zonal Cavity Method - Effective Floor Reflectance = 20% |
| ||||||||||||||
| 0 | .69 | .69 | .69 | .69 | .67 | .67 |
| .64 | .64 |
|
| .62 | .62 | .58 |
| ||
| 1 | .66 | .64 | .63 | .61 | .63 | .60 |
| .60 | .58 |
|
| .58 | .57 | .54 |
| ||
| 2 | .62 | .60 | .57 | .55 | .59 | .55 |
| .57 | .53 |
|
| .55 | .52 | .50 |
| ||
| 3 | .59 | .55 | .52 | .50 | .54 | .50 |
| .53 | .49 |
|
| .52 | .48 | .47 |
| ||
| 4 | .56 | .52 | .48 | .46 | .51 | .46 |
| .50 | .45 |
|
| .49 | .45 | .43 |
| ||
Ratio | 5 | .53 | .48 | .44 | .42 | .47 | .42 |
| .46 | .41 |
|
| .45 | .41 | .40 |
| ||
6 | .50 | .45 | .41 | .39 | .44 | .38 |
| .43 | .38 |
|
| .42 | .38 | .37 |
| |||
Cavity | 7 | .47 | .41 | .38 | .35 | .41 | .35 |
| .40 | .35 |
|
| .39 | .35 | .34 |
| ||
8 | .44 | .38 | .35 | .32 | .38 | .32 |
| .37 | .32 |
|
| .37 | .32 | .31 |
| |||
Room | 9 | .42 | .36 | .32 | .30 | .35 | .30 |
| .35 | .29 |
|
| .34 | .29 | .28 |
| ||
| 10 | .39 | .33 | .30 | .27 | .33 | .27 |
| .32 | .27 |
|
| .32 | .27 | .26 |
| ||
|
|
|
|
|
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 59.0
White Glass Reflector Catalog No. 41257U / 42WH, 57W CFL, 4300 Lumens.
CANDLEPOWER SUMMARY | ZONAL LUMENS AND PERCENTAGES |
COEFFICIENTS OF UTILIZATION |
250
500 | 60° |
750
1000
30°
Report No. 2645FR
SC = .9
ANGLE MEAN CP LMS
01139
51129 106
10 | 1037 |
|
15 | 930 | 264 |
20 | 832 |
|
25 | 744 | 343 |
30 | 639 |
|
35 | 511 | 323 |
40 | 394 |
|
45 | 302 | 241 |
50 | 244 |
|
55 | 208 | 189 |
60 | 184 |
|
65 | 170 | 170 |
70 | 159 |
|
75 | 151 | 160 |
80 | 145 |
|
85139 154
90140
ANGLE | MEAN CP | LMS | ZONE | LUMENS | % LAMP | %LUMINAIRE |
90 | 140 |
| 712 | 16.57 | 24.15 | |
95 | 148 | 162 | 1035 | 24.08 | 35.09 | |
100 | 156 |
| 1465 | 34.08 | 49.65 | |
105 | 163 | 172 | 1949 | 45.33 | 66.04 | |
110 | 168 |
| 913 | 21.25 | 30.95 | |
115 | 172 | 170 | 483 | 11.25 | 16.39 | |
120 | 175 |
| 1002 | 23.31 | 33.96 | |
125 | 176 | 157 | 2951 | 68.64 | 100.00 | |
130 | 175 |
|
|
|
|
|
135 | 173 | 133 |
| ** EFFICIENCY=68.6% ** | ||
140 | 169 |
|
|
|
|
|
145164 103
150157
155 | 147 | 68 |
160 | 133 |
|
165 | 114 | 32 |
170 | 87 |
|
175 | 55 | 6 |
180 | 42 |
|
Ceiling |
|
| 80% |
| 70% |
| 50% |
| 30% |
|
| ||||||
|
|
|
|
|
|
| |||||||||||
| Wall | 70 | 50 | 30 | 10 | 50 | 10 |
| 50 | 10 |
| 50 | 10 | 0 |
| ||
| RCR |
| Zonal Cavity Method - Effective Floor Reflectance = 20% |
| |||||||||||||
| 0 | .76 | .76 | .76 | .76 | .72 | .72 |
| .63 | .63 |
| .56 | .56 | .45 |
| ||
| 1 | .69 | .66 | .63 | .60 | .62 | .57 |
| .55 | .51 |
| .48 | .45 | .37 |
| ||
| 2 | .63 | .58 | .54 | .50 | .55 | .48 |
| .49 | .43 |
| .43 | .39 | .32 |
| ||
| 3 | .58 | .52 | .47 | .43 | .49 | .41 |
| .44 | .37 |
| .39 | .34 | .28 |
| ||
| 4 | .54 | .47 | .42 | .38 | .45 | .36 |
| .40 | .33 |
| .36 | .30 | .25 |
| ||
Ratio | 5 | .50 | .42 | .37 | .33 | .40 | .32 |
| .36 | .29 |
| .33 | .27 | .23 |
| ||
6 | .47 | .39 | .33 | .29 | .37 | .28 |
| .33 | .26 |
| .30 | .24 | .21 |
| |||
Cavity | 7 | .43 | .35 | .30 | .26 | .34 | .25 |
| .30 | .24 |
| .27 | .22 | .19 |
| ||
8 | .41 | .32 | .27 | .24 | .31 | .23 |
| .28 | .21 |
| .26 | .20 | .17 |
| |||
Room | 9 | .38 | .30 | .25 | .21 | .28 | .21 |
| .26 | .19 |
| .24 | .18 | .15 |
| ||
| 10 | .36 | .27 | .23 | .19 | .26 | .19 |
| .24 | .18 |
| .22 | .16 | .14 |
|
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 54.0
Amber Glass Reflector Catalog No. 41257U / 42AB, 57W CFL, 4300 Lumens.
CANDLEPOWER SUMMARY | ZONAL LUMENS AND PERCENTAGES |
COEFFICIENTS OF UTILIZATION |
325
60°
650
975
30°
1300
Report No. 2646FR
SC = .9
ANGLE MEAN CP LMS
01279
51263 118
10 | 1155 |
|
15 | 1040 | 295 |
20 | 932 |
|
25 | 835 | 384 |
30 | 713 |
|
35 | 565 | 356 |
40 | 427 |
|
45 | 312 | 249 |
50 | 233 |
|
55 | 176 | 161 |
60 | 134 |
|
65 | 103 | 104 |
70 | 77 |
|
75 | 55 | 59 |
80 | 35 |
|
85 | 18 | 21 |
90 | 5 |
|
ANGLE | MEAN CP | LMS | ZONE | LUMENS | % LAMP | %LUMINAIRE |
90 | 5 |
| 797 | 18.54 | 44.54 | |
95 | 5 | 6 | 1153 | 26.83 | 64.45 | |
100 | 6 |
| 1563 | 36.37 | 87.36 | |
105 | 7 | 7 | 1747 | 40.63 | 97.61 | |
110 | 7 |
| 593 | 13.80 | 33.16 | |
115 | 8 | 8 | 183 | 4.27 | 10.25 | |
120 | 8 |
| 42 | .99 | 2.39 | |
125 | 9 | 8 | 1789 | 41.63 | 100.00 | |
130 | 9 |
|
|
|
|
|
135 | 8 | 7 |
| ** EFFICIENCY = 41.6% ** | ||
140 | 8 |
|
|
|
|
|
145 | 8 | 5 |
|
|
|
|
150 | 7 |
|
|
|
|
|
155 | 5 | 2 |
|
|
|
|
160 | 4 |
|
|
|
|
|
165 | 2 | 1 |
|
|
|
|
170 | 1 |
|
|
|
|
|
175 | 0 | 0 |
|
|
|
|
180 | 0 |
|
|
|
|
|
Ceiling |
| 80% |
| 70% |
| 50% |
| 30% |
|
| ||||||
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Wall | 70 | 50 | 30 | 10 | 50 | 10 |
| 50 | 10 |
| 50 | 10 | 0 |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
RCR | Zonal Cavity Method - Effective Floor Reflectance = 20% |
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0 | .49 | .49 | .49 | .49 | .48 | .48 |
| .46 | .46 |
| .44 | .44 | .41 |
| ||
1 | .46 | .45 | .44 | .42 | .44 | .42 |
| .42 | .40 |
| .40 | .39 | .37 |
| ||
2 | .43 | .41 | .39 | .37 | .40 | .37 |
| .38 | .36 |
| .37 | .35 | .33 |
| ||
3 | .41 | .37 | .35 | .33 | .37 | .33 |
| .35 | .32 |
| .34 | .31 | .30 |
| ||
4 | .38 | .34 | .32 | .30 | .34 | .29 |
| .33 | .29 |
| .32 | .28 | .27 |
| ||
5 | .36 | .32 | .29 | .27 | .31 | .26 |
| .30 | .26 |
| .29 | .26 | .25 |
| ||
| Ratio6 | .34 | .29 | .26 | .24 | .29 | .24 |
| .28 | .24 |
| .27 | .24 | .23 |
| |
7 | .31 | .27 | .24 | .22 | .27 | .22 |
| .26 | .22 |
| .25 | .21 | .21 |
| ||
| Cavity8 | .30 | .25 | .22 | .20 | .25 | .20 |
| .24 | ..20 |
| .24 | .20 | .19 |
| |
9 | .28 | .23 | .20 | .18 | .23 | .18 |
| .22 | .18 |
| .22 | .18 | .17 |
| ||
10 | .26 | .22 | .19 | .17 | .21 | .17 |
| .21 | .17 |
| .20 | .17 | .16 |
| ||
|
| Room |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 54.0
Notes: Amber Glass and Cobalt Blue Glass have the same Photometrics.
Job Information | Type: |
|
|
631 Airport Road, Fall River, MA 02720 • (508)
Lightolier is a Philips group brand