Calculite® HID Lensed Downlight C4T4GD-MHT4R

Page 2 of 2

4 1/2" Aperture, T4.5 Ceramic Metal Halide, Glasslite

2,250

4,500

6,750

9,000

39W T4.5 CERAMIC MH, NARROW FLOOD UPPER REFLECTOR, PHILIPS, LUMEN RATING = 3400 LMS., AROMAT ELECTRONIC BALLAST

 

ANGLE

MEAN CP

LUMENS LUMINANCE SUMMARY - CD. / SQ. M.

 

 

 

 

Coefficients of Utilization

 

 

 

 

 

 

 

0

8996

 

ANGLE

MEAN CD/SQ M

 

 

 

 

 

 

 

 

 

 

 

 

5

7584

45

 

 

7690

CEILING

 

 

 

80%

 

 

70%

50%

 

30%

 

 

 

 

10

4322

 

 

 

 

 

 

 

 

 

 

 

 

55

 

 

6459

WALL

70

50

30

10

50

10

50

10

50

10

 

0

 

 

15

2225

 

 

 

 

 

65

 

 

3966

 

 

60°

20

1047

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RCR

 

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

 

 

75

 

 

2612

 

 

 

 

 

25

452

 

 

 

 

 

 

 

30

169

85

 

 

0

 

 

0

.56

.56

.56

.56

.54

.54

.52

.52

.50

.50

 

.47

 

 

35

81

 

 

 

 

 

 

1

.54

.53

.52

.51

.52

.51

.50

.49

.48

.48

 

.46

 

 

40

53

 

ZONAL LUMENS AND PERCENTAGES

2

.52

.51

.50

.49

.50

.48

.49

.47

.47

.46

 

.44

 

 

45

39

 

ZONE LUMENS

% LAMP

%LUMINAIRE

3

.51

.49

.48

.47

.48

.46

.47

.46

.46

.45

 

.44

 

 

50

32

 

0-30

1459

42.92

 

91.95

4

.50

.48

.46

.45

.47

.45

.46

.44

.45

.44

 

.43

 

 

55

26

 

0-40

1515

44.58

 

95.5

 

 

 

 

 

5

.49

.46

.45

.43

.46

.43

.45

.43

.44

.42

 

.42

 

 

60

20

 

0-60

1569

46.16

 

98.88

 

 

 

65

12

 

0-90

1587

46.68

 

100

6

.48

.45

.43

.42

.45

.42

.44

.42

.44

.42

 

.41

 

 

70

7

 

40-90

71

2.1

 

4.5

7

.46

.44

.42

.41

.44

.41

.43

.41

.43

.41

 

.40

 

 

75

5

 

60-90

17

0.52

 

1.12

8

.46

.43

.41

.40

.43

.40

.42

.40

.42

.40

 

.39

 

 

 

90-180

0

0

 

0

 

 

 

80

3

 

0-180

1587

46.68

 

100

9

.45

.42

.41

.39

.42

.39

.42

.39

.41

.39

 

.39

 

30°

85

0

 

 

 

 

 

 

10

.44

.41

.40

.38

.41

.38

.41

.38

.40

.38

 

.38

 

 

 

 

 

 

 

 

 

90

0

 

 

 

 

 

 

 

 

 

 

 

LUMINAIRE INPUT WATTS = 44

 

 

 

 

** EFFICIENCY = 46.7% **

CERTIFIED TEST REPORT NO. 18678FR, DATE: APRIL 2, 2004.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SC = .3

COMPUTED BY LSI PROGRAM **TEST-LITE**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

70W T4.5 CERAMIC MH, NARROW FLOOD UPPER REFLECTOR, PHILIPS, LUMEN RATING = 6200 LMS., AROMAT ELECTRONIC BALLAST

3,750

7,500

11,250

15,000

** EFFICIENCY = 42.4% ** SC = .3

ANGLE

MEAN CP

LUMENS LUMINANCE SUMMARY - CD. / SQ. M.

 

 

 

Coefficients of Utilization

 

 

 

 

 

 

0

13659

 

ANGLE

MEAN CD/SQ M

 

 

 

 

 

 

 

 

 

 

 

5

11121

915

45

 

15547

CEILING

 

 

 

 

80%

 

 

70%

50%

 

30%

 

 

 

10

6556

 

 

 

 

 

 

 

 

 

 

 

 

 

55

 

13566

WALL

 

70

50

30

10

50

10

50

10

50

10

 

0

 

15

3509

990

 

 

 

 

65

 

9819

 

 

60°

20

1859

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RCR

 

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

 

 

75

 

6013

 

 

 

25

942

441

 

 

 

 

30

400

 

85

 

2289

 

 

0

.50

.50

.50

.50

.49

.49

.47

.47

.45

.45

 

.42

 

35

177

125

 

 

 

 

 

1

.49

.48

.47

.46

.47

.46

.45

.44

.44

.43

 

.41

 

40

105

 

ZONAL LUMENS AND PERCENTAGES

 

2

.47

.46

.45

.44

.45

.43

.44

.42

.43

.41

 

.40

 

45

78

62

ZONE LUMENS

% LAMP %LUMINAIRE

 

3

.46

.44

.43

.42

.44

.41

.43

.41

.42

.40

 

.39

 

50

65

 

0-30

2346

37.85

89.35

 

4

.45

.43

.41

.40

.42

.40

.41

.39

.41

.39

 

.38

 

55

55

49

0-40

2471

39.87

94.11

 

 

 

 

5

.44

.41

.40

.39

.41

.38

.40

.38

.40

.38

 

.37

 

60

43

 

0-60

2582

41.65

98.32

 

 

 

65

29

30

0-90

2626

42.36

100

 

6

.43

.40

.39

.37

.40

.37

.39

.37

.39

.37

 

.36

 

70

20

 

40-90

154

2.49

5.89

 

7

.41

.39

.37

.36

.39

.36

.38

.36

.38

.36

 

.35

 

75

11

12

60-90

44

0.71

1.68

 

8

.41

.38

.36

.35

.38

.35

.37

.35

.37

.35

 

.34

 

90-180

0

0

0

 

 

 

80

6

 

0-180

2626

42.36

100

 

9

.40

.37

.36

.34

.37

.34

.37

.34

.36

.34

 

.34

30°

85

1

2

 

 

 

 

 

10

.39

.36

.35

.34

.36

.34

.36

.34

.36

.33

 

.33

 

 

 

 

 

900

LUMINAIRE INPUT WATTS = 78

CERTIFIED TEST REPORT NO.18753FR, DATE: APRIL 2, 2004.

COMPUTED BY LSI PROGRAM **TEST-LITE**

39W T4.5 CERAMIC MH, FLOOD UPPER REFLECTOR, PHILIPS, LUMEN RATING = 3400 LMS. AROMAT ELECTRONIC BALLAST

500

1,000

1,500

2,000

** EFFICIENCY = 33.1% ** SC = .7

ANGLE

MEAN CP

LUMENS LUMINANCE SUMMARY - CD. / SQ. M.

 

 

 

 

Coefficients of Utilization

 

 

 

 

 

 

0

1992

 

ANGLE

MEAN CD/SQ M

 

 

 

 

 

 

 

 

 

 

 

5

1944

184

45

 

7192

CEILING

 

 

 

80%

 

 

70%

50%

 

30%

 

 

 

10

1822

 

 

 

 

 

 

 

 

 

 

 

 

55

 

6459

 

WALL

70

50

30

10

50

10

50

10

50

10

 

0

 

15

1660

444

 

 

 

 

65

 

5333

 

 

60°

20

1226

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RCR

 

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

 

 

75

 

3973

 

 

 

 

25

706

322

 

 

 

 

 

 

 

 

85

 

2101

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

315

 

 

 

.39

.39

.39

.39

.37

.38

.38

.38

.35

.35

 

.33

 

35

139

95

 

 

 

 

 

1

.38

.37

.37

.36

.35

.37

.37

.35

.34

.33

 

.32

 

40

66

 

ZONAL LUMENS AND PERCENTAGES

 

2

.37

.35

.34

.33

.33

.36

.35

.33

.33

.32

 

.30

 

45

36

31

ZONE LUMENS

% LAMP %LUMINAIRE

 

3

.35

.34

.33

.31

.32

.35

.33

.31

.32

.30

 

.29

 

50

30

23

0-30

949

27.94

84.42

 

4

.34

.32

.31

.30

.30

.34

.32

.30

.31

.29

 

.28

 

55

26

0-40

1045

30.74

92.9

 

5

.33

.31

.30

.28

.29

.33

.31

.28

.30

.28

 

.27

 

60

21

 

0-60

1099

32.34

97.74

 

 

 

 

 

6

.32

.30

.28

.27

.28

.32

.30

.27

.29

.27

 

.26

 

65

16

16

0-90

1125

33.09

100

 

 

 

40-90

79

2.35

7.1

 

7

.31

.29

.27

.26

.27

.31

.29

.26

.28

.26

 

.25

 

70

11

 

 

 

 

 

60-90

25

0.75

2.26

 

8

.30

.28

.26

.25

.26

.30

.27

.25

.27

.25

 

.25

 

75

7

8

 

 

 

90-180

0

0

0

 

9

.29

.27

.25

.24

.25

.29

.27

.24

.26

.24

 

.24

 

80

4

 

0-180

1125

33.09

100

 

 

30°

85

1

2

 

 

 

 

 

10

.28

.26

.24

.23

.24

.28

.26

.23

.25

.23

 

.23

 

 

 

 

 

 

90

0

 

 

 

 

 

 

 

 

 

 

LUMINAIRE INPUT WATTS = 44

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CERTIFIED TEST REPORT NO.18679FR, DATE: APRIL 2, 2004.

COMPUTED BY LSI PROGRAM **TEST-LITE**

70W T4.5 CERAMIC MH, FLOOD UPPER REFLECTOR, PHILIPS, LUMEN RATING = 6200 LMS., AROMAT ELECTRONIC BALLAST

750

1,500

2,250

3,000

** EFFICIENCY = 32.6% ** SC = .7

ANGLE

MEAN CP

LUMENS LUMINANCE SUMMARY - CD. / SQ. M.

 

 

 

Coefficients of Utilization

 

 

 

 

 

 

 

0

3172

 

ANGLE

MEAN CD/SQ M

 

 

 

 

 

 

 

 

 

 

 

 

5

3144

303

45

 

13385

CEILING

 

 

 

 

80%

 

 

 

70%

50%

 

30%

 

 

 

 

10

3054

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55

 

11655

WALL

 

70

50

30

10

 

50

10

50

10

50

10

 

0

 

 

15

2810

763

 

 

 

 

 

 

65

 

9620

 

 

 

 

60°

20

2215

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RCR

 

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

 

 

 

75

 

7313

 

 

 

 

25

1361

618

 

 

 

 

 

 

 

 

85

 

4282

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

668

 

 

 

 

.39

.39

.39

.39

 

.38

.38

.36

.36

.35

.35

 

.33

 

 

35

279

194

 

 

 

 

 

 

1

.37

.37

.36

.35

 

.36

.35

.35

.34

.33

.33

 

.31

 

 

40

125

 

ZONAL LUMENS AND PERCENTAGES

 

2

.36

.35

.34

.33

 

.34

.32

.33

.32

.32

.31

 

.30

 

 

45

67

57

ZONE LUMENS

% LAMP %LUMINAIRE

 

3

.35

.33

.32

.31

 

.33

.31

.32

.30

.31

.30

 

.29

 

 

50

55

42

0-30

1684

27.16

83.2

 

4

.34

.32

.30

.29

 

.31

.29

.31

.29

.30

.29

 

.28

 

 

55

47

0-40

1878

30.29

92.79

 

5

.32

.30

.29

.28

 

.30

.28

.30

.28

.29

.27

 

.27

 

 

60

39

 

0-60

1977

31.9

97.71

 

 

 

 

 

 

 

6

.31

.29

.28

.27

 

.29

.27

.29

.27

.28

.26

 

.26

 

 

65

29

29

0-90

2024

32.65

100

 

 

 

 

 

40-90

145

2.35

7.21

 

7

.30

.28

.27

.26

 

.28

.25

.27

.25

.27

.25

 

.25

 

 

70

20

 

 

 

 

 

 

 

60-90

46

0.75

2.29

 

8

.29

.27

.26

.25

 

.27

.24

.27

.24

.26

.24

 

.24

 

 

75

13

14

 

 

 

 

 

90-180

0

0

0

 

9

.28

.26

.25

.24

 

.26

.24

.26

.23

.25

.23

 

.23

 

 

80

8

 

0-180

2024

32.65

100

 

 

 

 

30°

85

3

3

 

 

 

 

 

 

10

.28

.25 .24 .23

 

.25

.23

.25

.23

.25

.23

 

.22

 

 

 

 

 

 

 

 

 

90

0

 

 

 

 

 

 

 

 

 

 

 

LUMINAIRE INPUT WATTS = 78

 

 

 

 

 

 

CERTIFIED TEST REPORT NO.18755FR, DATE: APRIL 2, 2004.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMPUTED BY LSI PROGRAM **TEST-LITE**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Job Information

 

 

Type:

 

 

 

 

 

 

 

Lightolier a Genlyte Thomas Companywww.lightolier.com 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504

Page 2
Image 2