TAG 036: Developer Unit Not Installed

Error Code:

036

Possible Defects: Developer unit not installed properly

Connectors or wiring

PCL board

1 Turn the printer off and unplug the power cord.

Make sure the developer unit is installed properly.

Confirm that J/P41 is connected properly.

Confirm that the proper developer unit is installed.

Power-on-reset the printer.

Is error code 036 displayed?

No: A loose connector or improper developer unit was at fault. Turn to TAG 002: Check & Problem Resolution.

Yes: Continue.

2 Check the voltages, as described in Chapter 9, “General Printer Maintenance” .

Are the voltages correct?

No: Replace the high voltage power supply unit, then turn to TAG 002: Check & Problem Resolution.

Yes: Continue.

3 Turn the printer off and unplug the power cord.

Disconnect J/P41.

Check P41-45 to P41-46 for continuity.

Is there continuity?

No: Continue.

Yes: Replace the PCL board, then turn to TAG 002: Check & Problem Resolution.

4 Remove the developer unit.

Check P41-45 to J25-12 and P41-46 to J25-8 for continuity.

Is there continuity on both?

No: Repair or replace the connectors or wiring from: P41-45 to J25-12 or P41-46 to J25-8, then turn to TAG 002: Check & Problem Resolution.

Yes: Replace the developer unit, then turn to TAG 002: Check & Problem Resolution.