TAG 036: Developer Unit Not Installed
Error Code: | 036 |
Possible Defects: Developer unit not installed properly
Connectors or wiring
PCL board
1 Turn the printer off and unplug the power cord.
•Make sure the developer unit is installed properly.
•Confirm that J/P41 is connected properly.
•Confirm that the proper developer unit is installed.
•
Is error code 036 displayed?
No: A loose connector or improper developer unit was at fault. Turn to TAG 002: Check & Problem Resolution.
Yes: Continue.
2 Check the voltages, as described in Chapter 9, “General Printer Maintenance” .
Are the voltages correct?
No: Replace the high voltage power supply unit, then turn to TAG 002: Check & Problem Resolution.
Yes: Continue.
3 Turn the printer off and unplug the power cord.
•Disconnect J/P41.
•Check
Is there continuity?
No: Continue.
Yes: Replace the PCL board, then turn to TAG 002: Check & Problem Resolution.
4 Remove the developer unit.
•Check
Is there continuity on both?
No: Repair or replace the connectors or wiring from:
Yes: Replace the developer unit, then turn to TAG 002: Check & Problem Resolution.
Troubleshooting Analysis Guide (TAGs) |