20
•While the main motor is running, cover all of the holes in the vacuum unit with a piece of paper.
Does the vacuum transport unit fan hold the paper in place?
No: Continue.
Yes: Return to the beginning of this TAG.
21 Use extreme caution: Check for 100 Vac from
Is the voltage 100 Vac?
No: Continue.
Yes: Replace the vacuum transport assembly.
22
•While the main motor is running, monitor
Is the voltage 100 Vac?
No: Replace the power control board, then turn to TAG 002: Check & Problem Resolution.
Yes: Repair or replace the connectors or wiring from
Troubleshooting Analysis Guide (TAGs) |