(004 intentionally excluded)
011Main Charger Test1Remove the photoconductor unit and place it in its protective packaging. Close the top cover.
2Go to: 011
3Press: READY to run the test. The main charger turns on and off repeatedly.
4Confirm that the display alternates between “0” and “1,” accompanied each time by a brief tone. The display indicates the following:
Table
DisplayIndication
0Main charger off
1Main charger on
These codes may indicate specific error conditions:
Table
DisplayIndication
041Photoconductor seam sensor short
045Main charger short
046Main charger open
5Press: STOP to exit.
6Reinstall the photoconductor unit.