(004 intentionally excluded)

011Main Charger Test

1Remove the photoconductor unit and place it in its protective packaging. Close the top cover.

2Go to: 011

3Press: READY to run the test. The main charger turns on and off repeatedly.

4Confirm that the display alternates between “0” and “1,” accompanied each time by a brief tone. The display indicates the following:

Table 5-7. Main Charger Test Displays

DisplayIndication

0Main charger off

1Main charger on

These codes may indicate specific error conditions:

Table 5-8. Main Charger Test Error Displays

DisplayIndication

041Photoconductor seam sensor short

045Main charger short

046Main charger open

4-1 You forgot to remove the photoconductor

5Press: STOP to exit.

6Reinstall the photoconductor unit.

5-10