(004 intentionally excluded)

012Transfer Charger Test

1Remove the photoconductor unit and place it in its protective packaging. Close the top cover.

2Go to: 012

3Press: READY to run the test. The transfer charger turns on and off repeatedly.

4Confirm that the display alternates between “0” and “1,” accompanied each time by a brief tone. The display indicates the following:

Table 5-9. Transfer Charger Test Displays

DisplayIndication

0Transfer charger off

1Transfer charger on

These codes may indicate specific error conditions:

Table 5-10. Transfer Charger Test Error Displays

DisplayIndication

041Seam sensor (sender) short

050Transfer charger short

051Transfer charger open or not installed

4-1 You forgot to remove the photoconductor

5Press: STOP to exit.

6Reinstall the photoconductor unit.

Diagnostic Tests

5-11