Table
Type | Error | Description |
|
|
|
| 040 | PCL board sensed that the signal from the photoconductor seam |
|
| sensor either was not of sufficient amplitude or did not show the |
|
| proper timing. |
|
|
|
| 041 | PCL board detected an abnormally high amount of current needed |
Errors | 042 | to drive the photoconductor seam sensor LED (within the photo- |
PCL board detected an open connection to the photoconductor | ||
|
| conductor unit). |
Rotation |
| seam sensor LED (within the photoconductor unit). |
|
| |
044 | PCL board detected a signal from the | |
|
| unit indicating that either the main charger or transfer charger cir- |
OPC |
| cuits have an open connection. |
|
| |
045 | PCL board detected a signal from the | |
|
| unit indicating an abnormally high load on the bias voltage to the |
|
| main charger. |
|
|
|
| 046 | PCL board detected a signal from the |
|
| unit indicating an open connection in the main charger circuit (diag- |
|
| nostic test only). |
|
|
|
| 050 | PCL board detected a signal from the |
Errors | 051 | unit indicating an abnormally high load on the bias voltage to the |
PCL board detected a signal from the | ||
|
| transfer charger. |
HVPS |
| unit indicating an open connection in the transfer charger circuit |
| (diagnostic test only). | |
|
| |
|
|
|
| 055 | PCL board detected that the current needed to drive the erase |
|
| lamp assembly was either higher or lower than the specified limits. |
|
|
|
| 060 | PCL board detected that the exit paper sensor did not deactivate |
Jams |
| or the paper path sensor did not activate within the allotted time. |
|
| |
061 | PCL board detected that the duplex paper path sensor did not | |
Duplex |
| deactivate, the turnaround tray sensor did not activate in the allot- |
| ted time, or the duplex paper path sensor activated at POR. | |
|
| |
|
|
|
| 062 | PCL board detected that paper leaving the duplex turnaround tray |
|
| did not reach the timing sensor within the allotted time or the |
|
| duplex turnaround sensor was activated at POR. |
|
|
|
Errors | 070 | PCL board sensed, via the fuser thermistor, that the temperature of |
| the fuser unit did not change within the allotted time. | |
|
| |
|
|
|
| 071 | PCL board sensed an open connection in the fuser thermistor cir- |
Control |
| cuit |
|
| |
072 | PCL board sensed that the resistance of the fuser thermistor was | |
|
| too low indicating that the temperature of the fuser unit was higher |
Fuser |
| than the specified limit. |
|
| |
073 | too high indicating that the temperature of the fuser unit was lower | |
| PCL board sensed that the resistance of the fuser thermistor was | |
|
| than the specified limit. |
|
|
|
Printer and Troubleshooting Overview |