Table 1-1. Error Code Technical Definitions (Continued)

Type

Error

Description

 

 

 

 

040

PCL board sensed that the signal from the photoconductor seam

 

 

sensor either was not of sufficient amplitude or did not show the

 

 

proper timing.

 

 

 

 

041

PCL board detected an abnormally high amount of current needed

Errors

042

to drive the photoconductor seam sensor LED (within the photo-

PCL board detected an open connection to the photoconductor

 

 

conductor unit).

Rotation

 

seam sensor LED (within the photoconductor unit).

 

 

044

PCL board detected a signal from the high-voltage power supply

 

 

unit indicating that either the main charger or transfer charger cir-

OPC

 

cuits have an open connection.

 

 

045

PCL board detected a signal from the high-voltage power supply

 

 

unit indicating an abnormally high load on the bias voltage to the

 

 

main charger.

 

 

 

 

046

PCL board detected a signal from the high-voltage power supply

 

 

unit indicating an open connection in the main charger circuit (diag-

 

 

nostic test only).

 

 

 

 

050

PCL board detected a signal from the high-voltage power supply

Errors

051

unit indicating an abnormally high load on the bias voltage to the

PCL board detected a signal from the high-voltage power supply

 

 

transfer charger.

HVPS

 

unit indicating an open connection in the transfer charger circuit

 

(diagnostic test only).

 

 

 

 

 

 

055

PCL board detected that the current needed to drive the erase

 

 

lamp assembly was either higher or lower than the specified limits.

 

 

 

 

060

PCL board detected that the exit paper sensor did not deactivate

Jams

 

or the paper path sensor did not activate within the allotted time.

 

 

061

PCL board detected that the duplex paper path sensor did not

Duplex

 

deactivate, the turnaround tray sensor did not activate in the allot-

 

ted time, or the duplex paper path sensor activated at POR.

 

 

 

 

 

 

062

PCL board detected that paper leaving the duplex turnaround tray

 

 

did not reach the timing sensor within the allotted time or the

 

 

duplex turnaround sensor was activated at POR.

 

 

 

Errors

070

PCL board sensed, via the fuser thermistor, that the temperature of

 

the fuser unit did not change within the allotted time.

 

 

 

 

 

 

071

PCL board sensed an open connection in the fuser thermistor cir-

Control

 

cuit

 

 

072

PCL board sensed that the resistance of the fuser thermistor was

 

 

too low indicating that the temperature of the fuser unit was higher

Fuser

 

than the specified limit.

 

 

073

too high indicating that the temperature of the fuser unit was lower

 

PCL board sensed that the resistance of the fuser thermistor was

 

 

than the specified limit.

 

 

 

1-8

Printer and Troubleshooting Overview