16 Clean both the photoconductor LED and seam sensor using a cotton swab or compressed air.
•Run diagnostic 009.
•Using an oscilloscope connected to
Figure A
12V
0V
Figure B
12V
0V
7 ms
Is the signal adjusted to match that illustrated in Figure A?
No: Repeat this step until the signal has been adjusted properly.
Yes: Turn to TAG 002: Check & Problem Resolution.
Troubleshooting Analysis Guide (TAGs) |