How to Run Diagnostics

001 Operator Panel Test

1Turn the volume control on the operator panel up fully.

2Go to: 001

3Press: READY to run the test.

4Confirm that the tone sounds and all lights turn on and off continuously.

5Press: STOP to exit.

002Upper Cassette Test

1Make sure the upper paper cassette is installed with paper, the side and rear guides securely against the edges of the paper in the cassette.

2Go to: 002

3Press: READY to run the test.

4Refer to the chart below to confirm that the code that displays corresponds to the paper size in the cassette. (For example, if the cassette holds letter size paper, “1-3” should appear on the display.) This indicates the paper size sensor is working properly. The following codes indicate paper sizes:

Table 5-1. Paper Size Codes

Display

Indication

 

 

1-0

Cassette not installed

 

 

1-1

A4-size paper in use

 

 

1-2

B5-size paper in use

 

 

1-3

Letter-size paper in use

 

 

1-4

Legal-size paper in use

 

 

1-5

Executive 1 size paper in use

 

 

1-6

Executive 2 size paper in use

 

 

1-7

Executive 3 size paper in use

 

 

1-8

Envelopes in use

 

 

1-9

Undefined paper size

 

 

5Press: STOP to exit.

5-4