1Go to: 021
2Press: READY to run the test. The display registers the paper size installed in the unit, as outlined on the chart
3Verify the correct paper size, as follows:
Table
Display | Indication |
4Press: STOP to exit.
022 Envelope Fuser Solenoid Test1Remove the photoconductor unit and place it in its protective packaging.
2Go to: 022
3Press: READY to run the test. The main motor turns on and “0” appears on the dis- play.
4Press: READY again to activate the envelope fuser solenoid.
5Listen for a clicking sound and confirm that the display alternates between “0” and when the solenoid is activated. If you hear no clicking, either the machine does not have an envelope fuser installed or the solenoid is not working properly.
6Check for the following conditions:
Table
Display | Indication |
090 Cover is open. Close cover.
7Press: STOP to exit.
Diagnostic Tests |