19 Turn the printer off.
•Reconnect J/P22.
•Turn on the printer for
Was the power-on-reset successful?
No: Replace the vacuum transport unit, then turn to TAG 002: Check & Problem Resolution.
Yes: Replace the small cooling fan assembly, then turn to TAG 002: Check & Problem Reso- lution.
20 Reconnect J/P9.
•Disconnect J/P100.
•Install a new upper fuse in the AC power supply unit.
•Run diagnostic test 008 for approximately five seconds, then turn off the printer.
•Remove the fuse.
•Check the fuse for continuity.
Does the fuse have continuity?
No: Go to #23 in this TAG.
Yes: Continue.
21 Turn off the printer.
•Reconnect J/P100.
•Install a good upper fuse in the AC power supply unit.
•Disconnect J/P101.
•Run diagnostic test 008 for approximately five seconds, then stop.
•Remove the fuse.
•Check the fuse for continuity.
Does the fuse have continuity?
No: Replace the power control #3 board, then turn to TAG 002: Check & Problem Resolu- tion.
Yes: Continue.
22 Disconnect J/P19.
•Check
Is there continuity to ground?
No: Replace the jogging motor, then turn to TAG 002: Check & Problem Resolution.
Yes: Repair or replace the connectors or wiring from
23 Disconnect J/P4 and J/P9.
•Check
Is there continuity to ground?
No: Continue.
Yes: Repair or replace the connectors or wiring from