10 Verify that the toner patch sensor board connector, mounted on the developer unit, is connected properly.
Is it connected properly?
No: A loose connection was at fault. Turn to TAG 002: Check & Problem Resolution.
Yes: Replace the PCL board, then turn to TAG 002: Check & Problem Resolution.
11 Turn the printer off and unplug the power cord.
•Disconnect J/P41 and J/P24.
•Check
Is there continuity?
No: Repair or replace the connectors or wiring from
Yes: Continue.
12 Reconnect J/P24.
•Disconnect J/P23.
•Check
Is there continuity?
No: Continue.
Yes: Repair or replace the connectors or wiring from
13 Reconnect J/P23.
•Disconnect J/P85 from the high voltage unit.
•Check
Is there continuity?
No: Repair or replace the connectors or wiring from
Yes: Continue.
14 Reinstall the developer unit.
•Reconnect J/P85.
•Disconnect J/P41 and J/P24.
•Check
Is there continuity?
No: Repair or replace the connector or wiring from
Yes: Continue.
Troubleshooting Analysis Guide (TAGs) |