TAG 750: Counter Malfunction

Error Code:

750

Symptoms: Counter does not count Counter counts too often

Consumable components require replacement too frequently

Possible Defects: Counter assembly

Connectors or wiring

PCL board

1 Run diagnostic test 007.

Is the counter functioning properly?

No: Continue.

Yes: The counter is working correctly. Turn to TAG 002: Check & Problem Resolution.

2 Verify that J/P41, J/P81, and J/P82 are connected properly.

Run diagnostic test 007.

Is the counter functioning properly?

No: Continue.

Yes: Loose connectors were at fault. Turn to TAG 002: Check & Problem Resolution.

3 Is the counter either counting when it shouldn’t or counting too many times?

No: Go to #5 in this TAG.

Yes: Continue.

4 Replace the counter.

Run test prints.

Has the problem been resolved?

No: Replace the PCL board, then turn to TAG 002: Check & Problem Resolution.

Yes: The counter was at fault. Turn to TAG 002: Check & Problem Resolution.

5 Check TP4-26 for +24 Vdc.

Is the voltage +24 Vdc?

No: Replace the PCL board, then turn to TAG 002: Check & Problem Resolution.

Yes: Continue.

6 Check TP4-25 for +24 Vdc.

Is the voltage +24 Vdc?

No: Go to #8 in this TAG.

Yes: Continue.

3-140