4 Does the PRINTER OPEN light come on with all the covers closed?
No: Go to #25 in this TAG.
Yes: Continue.
5 Operate the top and front cover interlock switch actuators.
Are the interlock switch actuators working properly?
No: Repair or replace any defective actuator, then turn to TAG 002: Check & Problem Resolution .
Yes: Continue.
6 Use extreme caution: Check from
Is the voltage +100 Vac?
No: Continue.
Yes: Repair or replace the connectors or wiring from:
7 Turn the printer off and unplug the power cord.
•Remove the upper fuse in the AC power supply unit.
•Check the fuse for continuity.
Does the fuse have continuity?
No: Continue.
Yes: Go to #10 in this TAG.
8 Replace the upper fuse in the AC power supply unit.
•Reconnect the power.
•
Was the
No: Go to #14 in this TAG.
Yes: Continue.
9 Remove the developer unit.
•Run diagnostic test 010 for approximately 5 seconds, then stop.
•Turn the printer off and unplug the power cord.
•Remove the fuse.
•Check the fuse for continuity.
Does the fuse have continuity?
No: Go to #12 in this TAG.
Yes: A defective fuse was at fault. Turn to TAG 002: Check & Problem Resolution.
Troubleshooting Analysis Guide (TAGs) |