19 Turn the printer off.
•Reconnect J/P333.
•Disconnect J/P73, the DC cable for the attachment option.
•Turn the printer on.
•Check
Is the voltage +5 Vdc?
No: Replace the signal interface board, then turn to TAG 002: Check & Problem Resolution.
Yes: Replace the attachment option, then turn to TAG 002: Check & Problem Resolution.
20 Turn the printer off.
•Reconnect J/P333.
•Disconnect J/P323.
•Turn the printer on.
•Check
Is the voltage +5 Vdc?
No: Replace wire harness W127 or W128, then turn to TAG 002: Check & Problem Resolution .
Yes: Continue.
21 Turn the printer off.
•Disconnect J/P310, found inside the duplex tray.
•Check
Is there continuity to ground?
No: Replace the duplex control board #2, then turn to TAG 002: Check & Problem Resolution .
Yes: Repair or replace the connectors or wiring from
22 Turn the printer on. Use extreme caution:
•Check from
Is the voltage at least 100 Vac?
No: Continue.
Yes: Replace the DC power supply unit, then turn to TAG 002: Check & Problem Resolution.
23 Use extreme caution: Check from
Is the voltage at least 100 Vac?
No: Replace the AC power supply unit.
Yes: Repair or replace the connectors or wiring from:
then turn to TAG 002: Check & Problem Resolution.
Troubleshooting Analysis Guide (TAGs) |