(004 intentionally excluded)
008 Jogging Motor Test
1Go to: 008
2Press: READY to run the test. The output tray jogs back and forth.
3Confirm that a tone sounds each time the tray contacts the sensor at each side.
The codes in the following table indicate specific error conditions:
Table 5-4. Jogging Motor Test Error Displays
Display | Indication |
081Front tray sensor signal not received
082Rear tray sensor signal not received
083No signal received from either sensor
090Close covers
4Press: STOP to exit.
009 Photoconductor Test
1Go to: 009
2Press: READY to run the test. The main motor rotates the photoconductor belt.
3Confirm that a tone sounds repeatedly, indicating that the photoconductor belt is rotating.
These codes may indicate specific error conditions:
Table
Display | Indication |
|
|
030 | Developer bias short detected |
040Photoconductor seam sensor not received or detected
041 | Seam sensor (sender) short |
042Seam sensor (sender) open or the photoconductor is not installed
055 | Erase lamp malfunction |
4Press: STOP to exit
Diagnostic Tests |