Table
Type | Error | Description |
|
|
|
| 081 | PCL board activated the jogging motor but did not detect a change |
|
| in the signal from the front sensor in the job offset assembly (diag- |
|
| nostic test only). |
|
|
|
| 082 | PCL board activated the jogging motor but did not detect a change |
|
| in the signal from the rear sensor in the job offset assembly (diag- |
|
| nostic test only). |
|
|
|
| 083 | PCL board activated the jogging motor but did not detect a change |
Errors |
| in the signal from either the front or rear sensors in the job offset |
| assembly. | |
|
| |
|
|
|
| 084 | PCL board detected a signal from the duplex control board #2 indi- |
Jogger |
| cating that the registration side sensor did not activate after com- |
| mand was sent to the duplex control board #2 to turn on the resist | |
|
| motor (diagnostic test only). |
|
|
|
| 085 | PCL board detected a signal from the duplex control board #2 indi- |
|
| cating that the registration side sensor did not deactivate after a |
|
| command was sent to the duplex control board #2 to turn on the |
|
| resist motor (diagnostic test only). |
|
|
|
| 086 | PCL board detected a signal from the duplex control board #2 indi- |
|
| cating that either the registration side sensor was activated and |
|
| would not deactivate or was deactivated and would not activate |
|
| after a command was sent to the duplex control board #2 to turn on |
|
| the resist motor. |
|
|
|
| 090 | PCL board detected that one of the cover interlocks was not acti- |
Errors |
| vated (diagnostic test only). |
|
| |
097 | PCL board detected a signal from the IGS board indicating the | |
|
| absence of +12 Vdc. |
|
|
|
LVPS | 098 | PCL board detected a signal from the IGS board indicating the |
| absence of | |
|
| |
|
|
|
| 099 | PCL board detected a signal from the IGS board indicating the |
|
| absence of +24 Vdc. |
|
|
|
| 100, 102 | IGS board detected a failure of the PCL board status codes. |
|
|
|
| 101 | PCL board detected that the IGS board was in a halt state (diag- |
|
| nostic test only). |
|
|
|
| PCL board detected an error in the communication between the | |
|
| PCL board and the IGS board. |
|
|
|
Errors | PCL board detected an error during the internal diagnostic testing | |
| of the PCL board. | |
|
| |
|
|
|
Controller | 140 | PCL board detected an error during the internal diagnostic testing |
| of the PCL board. | |
|
| |
|
|
|
| 145 | PCL board detected an error during the internal diagnostic testing |
|
| of the PCL board. |
|
|
|
| PCL board detected an error during the internal diagnostic testing | |
|
| of the PCL board. |
|
|
|
| PCL board detected an error in the communication between the | |
|
| PCL board and the IGS board. |
|
|
|
| IGS board detected an error during the internal diagnostic testing | |
|
| of the IGS board. |
|
|
|