Table 1-1. Error Code Technical Definitions (Continued)

Type

Error

Description

 

 

 

 

081

PCL board activated the jogging motor but did not detect a change

 

 

in the signal from the front sensor in the job offset assembly (diag-

 

 

nostic test only).

 

 

 

 

082

PCL board activated the jogging motor but did not detect a change

 

 

in the signal from the rear sensor in the job offset assembly (diag-

 

 

nostic test only).

 

 

 

 

083

PCL board activated the jogging motor but did not detect a change

Errors

 

in the signal from either the front or rear sensors in the job offset

 

assembly.

 

 

 

 

 

 

084

PCL board detected a signal from the duplex control board #2 indi-

Jogger

 

cating that the registration side sensor did not activate after com-

 

mand was sent to the duplex control board #2 to turn on the resist

 

 

motor (diagnostic test only).

 

 

 

 

085

PCL board detected a signal from the duplex control board #2 indi-

 

 

cating that the registration side sensor did not deactivate after a

 

 

command was sent to the duplex control board #2 to turn on the

 

 

resist motor (diagnostic test only).

 

 

 

 

086

PCL board detected a signal from the duplex control board #2 indi-

 

 

cating that either the registration side sensor was activated and

 

 

would not deactivate or was deactivated and would not activate

 

 

after a command was sent to the duplex control board #2 to turn on

 

 

the resist motor.

 

 

 

 

090

PCL board detected that one of the cover interlocks was not acti-

Errors

 

vated (diagnostic test only).

 

 

097

PCL board detected a signal from the IGS board indicating the

 

 

absence of +12 Vdc.

 

 

 

LVPS

098

PCL board detected a signal from the IGS board indicating the

 

absence of ‚-12 Vdc.

 

 

 

 

 

 

099

PCL board detected a signal from the IGS board indicating the

 

 

absence of +24 Vdc.

 

 

 

 

100, 102

IGS board detected a failure of the PCL board status codes.

 

 

 

 

101

PCL board detected that the IGS board was in a halt state (diag-

 

 

nostic test only).

 

 

 

 

121-127

PCL board detected an error in the communication between the

 

 

PCL board and the IGS board.

 

 

 

Errors

130-134

PCL board detected an error during the internal diagnostic testing

 

of the PCL board.

 

 

 

 

 

Controller

140

PCL board detected an error during the internal diagnostic testing

 

of the PCL board.

 

 

 

 

 

 

145

PCL board detected an error during the internal diagnostic testing

 

 

of the PCL board.

 

 

 

 

160-182

PCL board detected an error during the internal diagnostic testing

 

 

of the PCL board.

 

 

 

 

199-215

PCL board detected an error in the communication between the

 

 

PCL board and the IGS board.

 

 

 

 

301-401

IGS board detected an error during the internal diagnostic testing

 

 

of the IGS board.

 

 

 

Printer and Troubleshooting Overview