TAG 751: Main Drive Motor Runs Continuously
Error Code: | 751 |
Possible Defects: Power control #2 board
Connectors or wiring
PCL board
1 Turn the printer off and unplug the power cord.
•Disconnect J/P12 and J/P40.
•Check
Is there continuity?
No: Replace the power control #2 board. If this resolves the problem, turn to TAG 002: Check
&Problem Resolution. If this does not resolve the problem, replace the PCL board, then turn to TAG 002: Check & Problem Resolution.
Yes: Repair or replace the connectors or wiring from
Troubleshooting Analysis Guide (TAGs) |