Table 2-1. Printer Error Codes (Continued)

Code

Printer Error Code Meaning

Go to TAG

 

 

 

071

Fuser thermistor open or no fuser

071

 

 

 

072

Fuser temperature too high

072

 

 

 

073

Fuser temperature too low

070

 

 

 

081

No front job offset sensor

083

 

 

 

082

No back job offset sensor

083

 

 

 

083

Job offset mechanism malfunction

083

 

 

 

084

Duplex tray registration sensor not activated

901

 

 

 

085

Duplex tray registration sensor not deactivated

901

 

 

 

086

Duplex registration tray malfunction

901

 

 

 

090

Cover open

900

 

 

 

097

DC +12v power failure

097

 

 

 

098

DC -12v power failure

098

 

 

 

099

DC +24v power failure

099

 

 

 

100

PCL board command timeou

100

 

 

 

101

IGS controller diagnostic failure

101

 

 

 

Table 2-2. PCL/IGS Communication Error Codes

 

 

 

 

Code

PCL/IGS Communication Error Code Meaning

Go to TAG

 

 

 

121

No controller command; PCL board VSC command asserted

201

 

 

 

122

Command tag asserted; VSC command not asserted

201

 

 

 

123

VSS not asserted; PCL board status tag asserted

201

 

 

 

124

VSS asserted after PCL board sent status

201

 

 

 

125

VSS not asserted again though PCL board expects it

201

 

 

 

126

Command tag asserted during data byte sequence

201

 

 

 

127

PCL board detected parity/overrun on command line

201

 

 

 

Table 2-3. PCL Error Codes

 

 

 

 

Code

PCL Error Code Meaning

Go to TAG

 

 

 

130

Address or length error at initial microcode load

130

 

 

 

131

Checksum error at initial microcode load

130

 

 

 

132

RAM error at initial microcode load

100

 

 

 

133

No next block at initial microcode load

130

 

 

 

134

Incorrect format in initial microcode load file

130

 

 

 

140

PCL board ROM checksum error at power on diagnostic

100

 

 

 

145

PCL board RAM error at power on diagnostic

100

 

 

 

2-4

TAG Cross- Reference Tables