Table
Code | Printer Error Code Meaning | Go to TAG |
|
|
|
071 | Fuser thermistor open or no fuser | 071 |
|
|
|
072 | Fuser temperature too high | 072 |
|
|
|
073 | Fuser temperature too low | 070 |
|
|
|
081 | No front job offset sensor | 083 |
|
|
|
082 | No back job offset sensor | 083 |
|
|
|
083 | Job offset mechanism malfunction | 083 |
|
|
|
084 | Duplex tray registration sensor not activated | 901 |
|
|
|
085 | Duplex tray registration sensor not deactivated | 901 |
|
|
|
086 | Duplex registration tray malfunction | 901 |
|
|
|
090 | Cover open | 900 |
|
|
|
097 | DC +12v power failure | 097 |
|
|
|
098 | DC | 098 |
|
|
|
099 | DC +24v power failure | 099 |
|
|
|
100 | PCL board command timeou | 100 |
|
|
|
101 | IGS controller diagnostic failure | 101 |
|
|
|
Table |
| |
|
|
|
Code | PCL/IGS Communication Error Code Meaning | Go to TAG |
|
|
|
121 | No controller command; PCL board VSC command asserted | 201 |
|
|
|
122 | Command tag asserted; VSC command not asserted | 201 |
|
|
|
123 | VSS not asserted; PCL board status tag asserted | 201 |
|
|
|
124 | VSS asserted after PCL board sent status | 201 |
|
|
|
125 | VSS not asserted again though PCL board expects it | 201 |
|
|
|
126 | Command tag asserted during data byte sequence | 201 |
|
|
|
127 | PCL board detected parity/overrun on command line | 201 |
|
|
|
Table |
| |
|
|
|
Code | PCL Error Code Meaning | Go to TAG |
|
|
|
130 | Address or length error at initial microcode load | 130 |
|
|
|
131 | Checksum error at initial microcode load | 130 |
|
|
|
132 | RAM error at initial microcode load | 100 |
|
|
|
133 | No next block at initial microcode load | 130 |
|
|
|
134 | Incorrect format in initial microcode load file | 130 |
|
|
|
140 | PCL board ROM checksum error at power on diagnostic | 100 |
|
|
|
145 | PCL board RAM error at power on diagnostic | 100 |
|
|
|
TAG Cross- Reference Tables |