10 Run test prints. Use extreme caution:

Check J/P22-1 to J/P22-2 for 100 Vac.

Is the voltage 100 vac?

No: Continue.

Yes: Replace the vacuum transport unit, then turn to TAG 002: Check & Problem Resolution.

11 Run test prints. Use extreme caution:

Check J/P13-6 to J/P13-3 for 100 Vac.

Is the voltage 100 vac?

No: Replace the power control #2 board, then turn to TAG 002: Check & Problem Resolution .

Yes: Repair or replace the connectors or wiring from J22-1 to P13-6 or J22-2 to P13-3, then turn to TAG 002: Check & Problem Resolution.

12 Inspect the fuser drive assembly and the fuser drive belt for damage or a slipping belt.

Are they in good working order?

No: Replace the parts that are defective, then turn to TAG 002: Check & Problem Resolution.

Yes: Replace the printhead assembly, then turn to TAG 002: Check & Problem Resolution.

Troubleshooting Analysis Guide (TAGs)

3-179