5 Reconnect the main charger high voltage lead.
•Disconnect P23 and J/P41.
•Check
Is there continuity?
No: Repair or replace the connectors or wiring from
Yes: Continue.
6 Check
Is there continuity?
No: Repair or replace the connectors or wiring from
Yes: Replace the high voltage unit. If this corrects the problem, turn to TAG 002: Check & Problem Resolution. If this does not correct the problem, replace the PCL board, then turn to TAG 002: Check & Problem Resolution.
Troubleshooting Analysis Guide (TAGs) |