6 Open the back cover and install an interlock
•
•Check
Is the voltage +24 Vdc?
No: Go to #11 in this TAG.
Yes: Continue.
7 Check
Is the voltage +24 Vdc?
No: Repair or replace the connectors or wiring from
Yes: Continue.
8 Turn the printer off and unplug the power cord.
•Disconnect J/P41 and J/P24.
•Check the following for continuity:
Is there continuity?
No: Repair or replace the connectors or wiring from:
Then turn to TAG 002: Check & Problem Resolution.
Yes: Continue.
9 Disconnect P85 from the high voltage unit.
•Check
Is there continuity?
No: Repair or replace the connectors or wiring from
Yes: Continue.
10 Disconnect J/P96.
•Check
Is there continuity?
No: Repair or replace the developer power supply lead from
Yes: Replace the high voltage unit, then turn to TAG 002: Check & Problem Resolution.