7 Run test prints.
•Check
Does the voltage change from +24 Vdc to 0 Vdc?
No: Replace the PCL board, then turn to TAG 002: Check & Problem Resolution.
Yes: Replace the counter, then turn to TAG 002: Check & Problem Resolution.
8 Turn the printer off and unplug the power cord.
•Disconnect J/P41 and J/P82.
•Check
Is there continuity?
No: Repair or replace the connectors or wiring from
Yes: Continue.
9 Check
Is there continuity?
No: Repair or replace the connectors or wiring from
Yes: Replace the counter. If this resolves the problem, turn to TAG 002: Check & Problem Resolution. If this does not resolve the problem, replace the PCL board, then turn to TAG 002: Check & Problem Resolution.
Troubleshooting Analysis Guide (TAGs) |