TAG 100: PCL Board Interface Malfunction

Error Code: 100, 132, 140, 145, 160-162, 170-172, 180-182

Symptoms:

PCL board failure

Possible Defects: Connectors or wiring

PCL board

1 Turn off the printer and unplug the power cord.

Verify that J/P40, J/P41, J/P33, and J/P91 are connected properly.

Power-on-reset the printer.

Has the problem been resolved?

No: Continue.

Yes: A loose connector was at fault. Turn to TAG 002: Check & Problem Resolution.

2 Was an error code displayed during the power-on-reset?

No: Refer to the mechanical malfunctions cross-reference table in “Mechanical Malfunction/ TAG Cross-Reference” on page 2-12 .

Yes: Continue.

3 Was the error code the same as the one used to enter this TAG?

No: Refer to the error code cross-reference table in “Error Code/TAG Cross-Reference” on page 2-3.

Yes: Replace the PCL board, then turn to TAG 002: Check & Problem Resolution.

3-102