TAG 100: PCL Board Interface Malfunction
Error Code: 100, 132, 140, 145,
Symptoms: | PCL board failure |
Possible Defects: Connectors or wiring
PCL board
1 Turn off the printer and unplug the power cord.
•Verify that J/P40, J/P41, J/P33, and J/P91 are connected properly.
•
Has the problem been resolved?
No: Continue.
Yes: A loose connector was at fault. Turn to TAG 002: Check & Problem Resolution.
2 Was an error code displayed during the
No: Refer to the mechanical malfunctions
Yes: Continue.
3 Was the error code the same as the one used to enter this TAG?
No: Refer to the error code
Yes: Replace the PCL board, then turn to TAG 002: Check & Problem Resolution.
Troubleshooting Analysis Guide (TAGs) |