15 Reconnect J/P24.
•Disconnect J/P23.
•Check
Is there continuity?
No: Repair or replace the connectors or wiring from
Yes: Continue.
16 Remove the developer unit.
•Check
Is there continuity?
No: Repair or replace the connectors or wiring from
Yes: Continue.
17 Is a meter with a high voltage probe available?
No: Go to #19 in this TAG.
Yes: Continue.
18 Reinstall the developer unit.
•Reconnect J/P85.
•Run test prints.
•Using a high voltage probe, check
Is the voltage correct?
No: Replace the high voltage unit, then turn to TAG 002: Check & Problem Resolution.
Yes: Go to #20 in this TAG.
19 Reconnect J/P85.
•Reinstall the developer unit.
•Replace the high voltage unit.
•Run test prints.
Has the problem been resolved?
No: Reinstall the original high voltage unit and continue.
Yes: Turn to TAG 002: Check & Problem Resolution.