19 Turn the printer off and unplug the power cord.
•Disconnect J/P70 and J/P10.
•Check
Is there continuity?
No: Repair or replace the connectors or wiring from
Yes: Continue.
20 Check
Is there continuity?
No: Repair or replace the connectors or wiring from
Yes: Continue.
21 Reconnect J/P70.
•Connect negative lead of meter to
Is the resistance approximately 550KΩ?
No: Replace the AC power supply, then turn to TAG 002: Check & Problem Resolution.
Yes: Continue.
22 Disconnect J/P12.
•Check
Is there continuity?
No: Continue.
Yes: Replace the power control #2 board, then turn to TAG 002: Check & Problem Resolution .
23 Reconnect J/P10 and J/P12.
•Disconnect J/P40.
•Check
Is there continuity?
No: Replace the PCL board, then turn to TAG 002: Check & Problem Resolution.
Yes: Repair or replace the connectors or wiring from
24
•Check
Does the voltage change from +24 Vdc to 0 Vdc?
No: Replace the PCL board, then turn to TAG 002: Check & Problem Resolution.
Yes: Go to #11 in this TAG.