6 Run diagnostic test 008.

Caution

Check J/P101-2 to J/P101-1 for 100 Vac while the test is running

Is the voltage 100 Vac?

No: Go to #9 in this TAG.

Yes: Continue.

7 Turn the printer off.

Disconnect J/P101 and J/P19.

Check P101-2 to P19-1 for continuity.

Is there continuity?

No: Repair or replace the connectors or wiring from P101-2 to P19-1, then turn to TAG 002: Check & Problem Resolution.

Yes: Continue.

8 Check P101-1 to P19-3 for continuity.

Is there continuity?

No: Repair or replace the connector or wiring from P101-1 to P19-3, then turn to TAG 002: Check & Problem Resolution.

Yes: Repair or replace the job offset assembly, then turn to TAG 002: Check & Problem Reso- lution.

9 Run diagnostic test 008.

Check J/P102-2 for +12 Vdc while the test is running.

Is the voltage +12 Vdc?

No: Go to #11 in this TAG.

Yes: Replace the power control #3 board, then turn to TAG 002: Check & Problem Resolu- tion.

10 Run diagnostic test 008.

Check TP3-32 on the PCL board for +12 Vdc while the test is running.

Is the voltage +12 Vdc?

No: Repair or replace the connectors or wiring from P102-2 to P40-32, then turn to TAG 002: Check & Problem Resolution.

Yes: Replace the PCL board, then turn to TAG 002: Check & Problem Resolution.

3-76

Troubleshooting Analysis Guide (TAGs)

Page 128
Image 128
HP C30 manual Is the voltage +12 Vdc?