6 Run diagnostic test 008.
Caution
Check
Is the voltage 100 Vac?
No: Go to #9 in this TAG.
Yes: Continue.
7 Turn the printer off.
•Disconnect J/P101 and J/P19.
•Check
Is there continuity?
No: Repair or replace the connectors or wiring from
Yes: Continue.
8 Check
Is there continuity?
No: Repair or replace the connector or wiring from
Yes: Repair or replace the job offset assembly, then turn to TAG 002: Check & Problem Reso- lution.
9 Run diagnostic test 008.
•Check
Is the voltage +12 Vdc?
No: Go to #11 in this TAG.
Yes: Replace the power control #3 board, then turn to TAG 002: Check & Problem Resolu- tion.
10 Run diagnostic test 008.
•Check
Is the voltage +12 Vdc?
No: Repair or replace the connectors or wiring from
Yes: Replace the PCL board, then turn to TAG 002: Check & Problem Resolution.
Troubleshooting Analysis Guide (TAGs) |