Switch Integration Device Problems
Remedy: | Refer to Chapter 8, "Switch Integration Device |
| Administration", and set the baud rate correctly. |
|
|
Possible Reason: | The baud rate for the |
| not be set correctly. |
Remedy: | Refer to Chapter 8, "Switch Integration Device |
| Administration" and set the baud rate correctly. |
|
|
Calls are integrated but the message waiting lamp (MWL) does not work.
Possible Reason: | The MWL may not be administered correctly on the |
| INTUITY System. |
Remedy: | Check the administration of the system using Chapter |
| 6 of this document |
|
|
Possible Reason: | The packet format and MWL codes are set incorrectly |
| on the switch. |
Remedy: | Refer to Chapter 7, "NEAX 2400 Switch Administration" |
| and set the information correctly. |
|
|
Possible Reason: | The SMDI cable between the INTUITY System and the |
| SID may be defective. |
Remedy: | Replace the cable. |
|
|
You receive constant MWI Packet error messages.
Possible Reason: | The |
Remedy: | Replace the cable. |
|
|
Possible Reason: | The baud rate and parity are not configured correctly |
| on the SID. |
Remedy: | Refer to Chapter 8, "Switch Integration Device |
| Administration" for instructions on configuring the baud |
| rate and parity for the MCI link and the SMDI link. |
|
|
The LCD display contains the message Waiting for Remote Access.
Possible Reason: | You did not connect an analog phone line to the |
| modem port. |
Remedy: | Refer to Chapter 4, "Hardware Installation" for |
| instructions on connecting an analog phone line to the |
| modem port. |
|
|
Issue 2 December 1995