Switch Integration Device Problems

Remedy:

Refer to Chapter 8, "Switch Integration Device

 

Administration", and set the baud rate correctly.

 

 

Possible Reason:

The baud rate for the SID-to-PBX MCI connection may

 

not be set correctly.

Remedy:

Refer to Chapter 8, "Switch Integration Device

 

Administration" and set the baud rate correctly.

 

 

Calls are integrated but the message waiting lamp (MWL) does not work.

Possible Reason:

The MWL may not be administered correctly on the

 

INTUITY System.

Remedy:

Check the administration of the system using Chapter

 

6 of this document

 

 

Possible Reason:

The packet format and MWL codes are set incorrectly

 

on the switch.

Remedy:

Refer to Chapter 7, "NEAX 2400 Switch Administration"

 

and set the information correctly.

 

 

Possible Reason:

The SMDI cable between the INTUITY System and the

 

SID may be defective.

Remedy:

Replace the cable.

 

 

You receive constant MWI Packet error messages.

Possible Reason:

The RS-232 MCI cable may be defective.

Remedy:

Replace the cable.

 

 

Possible Reason:

The baud rate and parity are not configured correctly

 

on the SID.

Remedy:

Refer to Chapter 8, "Switch Integration Device

 

Administration" for instructions on configuring the baud

 

rate and parity for the MCI link and the SMDI link.

 

 

The LCD display contains the message Waiting for Remote Access.

Possible Reason:

You did not connect an analog phone line to the

 

modem port.

Remedy:

Refer to Chapter 4, "Hardware Installation" for

 

instructions on connecting an analog phone line to the

 

modem port.

 

 

Issue 2 December 1995 A-3

Page 115
Image 115
AT&T 2400 manual You receive constant MWI Packet error messages