Configuring the Message Center Interface Link

Use the following instructions to configure the UCD group with the MCI link.

1.At the INSTALLATION COMMANDS menu, shown in Figure 7-6.,enter 1 to select the System Data option. After you press ENTER , you see the ASSIGNMENT OF STATION DATA screen as shown in Figure 7-10.

Assignment of System Data

 

 

 

SYS: 2

 

TN:

1

SYS

: System Data Items

INDEX:

6

DATA:

 

01

1-System

Data 1

 

 

 

 

 

2-System

Data 2

 

 

 

 

 

3-System

Data 3

 

 

 

 

TN

: Tenant Number

 

 

 

 

INDEX: System Data Index

 

 

 

 

 

System

Index

 

 

 

 

 

1

0-255

 

 

 

 

 

2

0-15

 

 

 

 

 

3

0-31

DATA : System Data (Hexa-decimal)

Figure 7-10. Assignment of System Data

2.Enter 2 in the SYS field to tell the switch to associate the MCI link with a UCD group on a tenant by tenant basis.

3.Enter 1 in the TN field. You must use the same tenant value that you used to create the analog stations and UCD groups.

4.Enter 6 in the INDEX field. The value contains fields that allow the system to associate the MCI link with the UCD group or groups.

Issue 2 December 1995 7-17

Page 87
Image 87