Appendix F: Error Messages and Troubleshooting

Appendix F: Error Messages

and Troubleshooting

Under certain circumstances, the meter display on the speaker will indicate an “error message.” Following is a list of conditions that cause an error message to be displayed, and the corrective action required to cancel the error message.

LIST OF ERROR MESSAGES:

Error

Cause

No Mic Found

Mic is not connected during

 

RMC calibration

Speaker ID Error

Improper DIP switch setting.

 

Rear panel DIP switch on this

 

speaker set to all switches off,

 

or 2 or more speakers have

 

same ID setting

Sync Signal Error

No digital signal found or loss

 

of sync signal when the S/

 

PDIF or AES/EBU digital input

 

is selected.

MUTE

A speaker that is muted

 

indicates mute is active.

 

Speaker may be muted by

 

pressing individual or system

 

Mute button (in LSR4300

 

Control Center Software), or

 

activating SOLO on another

 

speaker.

Display Looks Like

RMC button blinks and the meter lights sequentially from right to left

All front panel buttons blink and the meter shows 5 segments moving back and forth on the speaker showing the error

The Input button will blink and the fi rst meter LED will fl ash to show muted state

First meter LED will blink. No other meter segments will be active.

Remedy

Press RMC to exit RMC. Connect mic and press and hold to calibrate.

Correct DIP switch settings.

Confi rm digital signal is connected.

Un-mute individual speaker or system mute, exit solo on other speakers.

Reset

Non-standard DIP switch

All front panel buttons

 

confi guration used to restore

and meter fl ash rapidly to

 

factory settings. This mode

indicate reset.

 

is entered by setting all DIP

 

 

switches ON and re-powering

 

 

the speaker.

 

Reset DIP switches so only a single DIP switch is active on each speaker and re-power.