Appendix C: Wiring Requirements
Diagram D details the connections using single conductor shielded cable with a Tip/Ring/ Sleeve or XLR plug for the LSR4328P / LSR4326P input. Single conductor cable should be used as a last resort as it provides the greatest likelihood of problems. The “HOT” (+) signal should be connected to the tip of the Tip/Ring/Sleeve plug. The GROUND should be attached to the Ring of the Tip/Ring/Sleeve plug at the LSR4328P / LSR4326P input.
Diagram E details the connections using unbalanced cable and Tip/Sleeve connections to the 1/4″ or XLR input.
Digital Audio Connections
Always use
We recommend the use of 110 ohm balanced cabling for AES/EBU connections, with a maximum cable length of 100 meters (approximately 330 feet). 75 ohm cabling should be used for S/PDIF connections, with a maximum cable length of 10 meters (approximately 33 feet).
36