Issue 2 December 1995 7-7
Assign Voice Mail Extensions to a UCD Group
1. At the Station Data Commands Menu shown in Figure 7-2., enter 13 to
select the Assignment of Station Hunting-UCD option. After you enter the
selection, you see the Assignment Of Station Hunting - UCD screen as
shown in Figure 7-4.
Figure 7-4. Assignment of Station Hunting -UCD Screen
2. In the TN field, enter the Tenant Num ber you assigned to the analog voice
mail ports. The system shows a default value of 1 in the field.
After you press , the cursor moves to the STN field.
3. In the STN field, enter the number you assigned as the first voice mail port
extension. After you enter the station number, the cursor moves to the
CNT field.
For example, in t he previous section a group of analog voice mail ports
was assigned extensions 500, 501, 502, and 503. 500 was the first
extension assigned.
4. In the CNT (count) field, enter the number of extensions you need to
include in the UCD group. After you enter the count, the cursor moves to
the second STN fiel d.
For example, to set up a UCD group using extensions 500, 501, 5 02, and
503, enter 4.
Assignment of Station Hunting - UCD
TN: 1 TN : Tenant Number
STN: 500 STN: Station Number
CNT: 4 2 STN: 501 CNT: Number of Stations to entered
(Recommend Max of 20 stations)
ADD: Number of Stations to be added
(Recommend Max of 20 stations)
*STN: Station Numbers of the Stations
included in the UCD group
(* indicates the order of
a station in the group)
ENTER