Switch Integration Device Administration

6.To change the default value shown, press the left or right arrow key to toggle through the optional values. The value you set for the baud rate must equal the value set for the SID to the INTUITY System communication link baud rate. Do not set two different values for these links. Stop pressing the arrow keys when you find the value you want to use.

NOTE:

In Chapter 3 you completed worksheet A which contained lines for the MCI baud rate and the SMDI baud rate. Refer to the worksheet to review the baud rates you selected. For the INTUITY system, the baud must be set to 2400.

7.After you select a baud rate, press to confirm your choice and move to the next form.

After you press enter, you see the PARITY form as shown in the following example:

MCI

Parity:

EVEN

<- ->1

8.To change the default parity value shown in the field, press the left or right arrow key to toggle through the optional values. Stop pressing the arrow keys when you find the parity value you want to use.

9.After you select a parity, press to confirm your choice and move to the next form.

After you press enter, you see the BYTE LENGTH form as shown in the following example:

MCI

Byte Length:

7 Bits

<- ->1

10.To change the default byte length shown in the field, press the left or right arrow key to toggle through the optional values. Stop pressing the arrow keys when you find the byte length you want to use.

11.After you select a byte length, press to confirm your choice and move to the last form.

After you press the key, you see the STOP BITS form as shown in the following example:

MCI

Stop Bits:

1

<- ->1

8-10Issue 2 December 1995