Hardware Installation

Use the following instructions to connect the MCI line to the NEAX 2400 switch.

1.Set the MCI I/O port (PN PAIO02) at the same baud rate as the SID, 2400 baud. Use Table 4-1to set the DIP switches on the MCI I/O port.

NOTE:

To set the baud rate for the MCI Link, you must set switches 1, 2, and 3 in a specific combination. For example, to set the baud rate at 2400BPS, set switch 1 to ON, switch 2 to OFF, and switch 3 to OFF.

Table 4-1. MCI I/O Port DIP-Switch SW01 or SW11 Settings for Switches 1 through 3

Switch Number

1

2

3

Function

 

 

 

 

 

 

 

ON

ON

ON

300BPS

 

 

 

 

 

 

 

ON

ON

OFF

600BPS

 

 

 

 

 

 

Settings

ON

OFF

ON

1200BPS

 

 

 

 

 

ON

OFF

OFF

2400BPS

 

 

 

 

 

 

 

 

OFF

ON

ON

4800BPS

 

 

 

 

 

 

 

OFF

ON

OFF

9600BPS

 

 

 

 

 

 

 

 

 

 

 

 

4-4Issue 2 December 1995