Table 4-3. MCI I/O Port DIP-Switch SW02 or SW12 Settings for Switches 1 through 8

Switch

Setting

Function

Number

 

 

 

 

 

1

ON

When PB lead is - terminal is busy

 

 

OFF

When PB lead is + terminal is busy

 

 

 

 

2

ON

DTR signal is always ON

 

 

OFF

DTR signal is controlled by the CPU

 

 

 

 

3

ON

DSR signal is not provided

 

 

OFF

DSR signal is provided

 

 

 

 

4

ON

CD is not provided

 

 

OFF

CD is provided

 

 

 

 

5

ON

CS is not provided

 

 

OFF

CS is provided

 

 

 

 

6

ON

CI is not provided

 

 

OFF

CI is provided

 

 

 

 

7

ON

PB signal is not provided

 

 

OFF

PB signal is provided

 

 

 

 

8

OFF

Not used

 

 

 

NOTE:

Recommended Default Settings:

If you use port 0, configure switches 01 and 02. If you use port 1, configure switches 11 and 12.

Standard switch settings for SW01 or SW11 are 1 ON, 2 OFF, 3 ON, 4 OFF, 5 OFF, 6 OFF, 7 ON, and 8 ON.

Standard switch settings for SW02 or SW12 are 1 ON, 2 ON, 3 ON, 4 ON, 5 ON, 6 ON, 7 ON, and 8 OFF.

3.Connect one end of a 25-pair cable to the MCI I/O port on the switch. To create the cable, refer to Table 4-4for the correct cable pinouts.

4-6Issue 2 December 1995

Page 48
Image 48
AT&T 2400 manual When PB lead is terminal is busy