Hardware Installation
Table
Switch | Setting | Function | |
Number | |||
|
| ||
|
|
| |
1 | ON | When PB lead is - terminal is busy | |
|
| ||
OFF | When PB lead is + terminal is busy | ||
| |||
|
|
| |
2 | ON | DTR signal is always ON | |
|
| ||
OFF | DTR signal is controlled by the CPU | ||
| |||
|
|
| |
3 | ON | DSR signal is not provided | |
|
| ||
OFF | DSR signal is provided | ||
| |||
|
|
| |
4 | ON | CD is not provided | |
|
| ||
OFF | CD is provided | ||
| |||
|
|
| |
5 | ON | CS is not provided | |
|
| ||
OFF | CS is provided | ||
| |||
|
|
| |
6 | ON | CI is not provided | |
|
| ||
OFF | CI is provided | ||
| |||
|
|
| |
7 | ON | PB signal is not provided | |
|
| ||
OFF | PB signal is provided | ||
| |||
|
|
| |
8 | OFF | Not used | |
|
|
|
NOTE:
Recommended Default Settings:
■If you use port 0, configure switches 01 and 02. If you use port 1, configure switches 11 and 12.
■Standard switch settings for SW01 or SW11 are 1 ON, 2 OFF, 3 ON, 4 OFF, 5 OFF, 6 OFF, 7 ON, and 8 ON.
■Standard switch settings for SW02 or SW12 are 1 ON, 2 ON, 3 ON, 4 ON, 5 ON, 6 ON, 7 ON, and 8 OFF.
3.Connect one end of a