PHOTOMETRY
Section 2A/Folio G50-83 REV. B

DEEPCELL SURFACE DPB2S32LS432

Page 2 of 2 2' x 4' SURFACE FLUORESCENT, 3" TYPE, 32 CELL PARABOLIC LOUVER, 4 LAMP T8 OR T12

PHOTOMETRY

G90057

DPB2S32LS432120O4

F32/T8

MODEL NO. DPB2S32LS432120O4 coefficients of utilization — zonal cavity method

 

RF

 

20

 

 

20

 

 

20

 

 

RC

 

80

 

 

50

 

 

30

 

 

RW

70

50

30

50

30

10

50

30

10

 

1

66

64

63

61

59

58

58

57

56

ratio

2

62

59

56

56

53

51

54

52

50

3

58

53

50

51

48

46

49

47

45

cavity

4

54

48

44

46

43

40

45

42

40

5

50

44

39

42

38

35

41

38

35

room

6

46

39

35

38

34

31

37

34

31

7

43

36

31

34

30

28

33

30

27

 

8

39

32

27

31

27

24

30

27

24

 

9

36

29

24

28

24

21

27

23

21

 

10

34

26

22

25

21

19

25

21

18

visual comfort probability

room size

 

 

 

 

ceiling height

 

 

 

 

ceiling height

 

W

L

 

8.5

10.0

13.0

16.0

 

 

8.5

10.0

13.0

16.0

20

20

 

 

85

76

70

75

 

 

90

80

74

75

20

30

 

 

87

80

74

70

 

 

91

83

78

78

20

40

 

 

87

83

78

73

 

 

91

85

82

81

20

60

 

 

88

83

81

76

 

 

91

85

84

83

30

20

 

 

85

80

73

73

 

 

90

84

76

74

30

30

 

 

87

83

77

69

 

 

91

86

80

76

30

40

 

 

88

85

80

73

 

 

91

87

83

79

30

60

 

lengthwise

88

85

83

76

 

crosswise

91

88

85

82

40

40

 

88

85

83

75

 

91

88

85

80

30

80

 

 

88

85

83

76

 

 

91

88

85

82

40

20

 

 

85

80

76

75

 

 

90

84

78

75

40

30

 

luminaries

88

84

80

72

 

luminaries

91

86

83

77

60

30

 

88

84

80

73

 

91

87

83

80

40

60

 

 

88

85

84

78

 

 

92

88

86

83

40

80

 

 

88

85

84

78

 

 

92

88

86

83

40

100

 

 

88

85

84

78

 

 

92

88

86

83

60

40

 

 

88

85

83

77

 

 

92

88

85

82

60

60

 

 

88

85

84

80

 

 

92

88

87

84

 

 

60

80

 

 

88

85

84

80

 

 

92

88

87

84

60

100

 

 

88

85

84

80

 

 

92

88

87

84

100

40

 

 

88

85

83

77

 

 

92

88

85

83

100

60

 

 

88

85

84

80

 

 

92

88

87

84

100

80

 

 

88

85

84

80

 

 

92

88

87

85

100

100

 

 

88

85

84

80

 

 

92

88

87

85

ORDERING INFORMATION Explanation of Catalog Number. Example: DPB2S32LS432120O4GLR

DP

 

B

 

2

 

S

 

32

 

 

 

S

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DEEPCELL

 

 

FIXTURE

 

 

 

NUMBER OF

 

BALLAST

PARABOLIC:

 

 

WIDTH

 

 

 

CELLS

 

COVER

Pre-

 

 

 

 

 

 

 

 

 

 

 

 

anodized

 

 

 

 

 

 

 

 

 

 

 

 

Aluminum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BODY STYLE:

 

 

 

CEILING

 

 

LOUVER FINISH*:

 

 

Surface Box

 

 

 

TYPE:

 

L= Low-iridescence semi-specu-

 

 

 

 

 

 

 

S=Surface

 

lar

 

 

 

 

 

 

 

 

 

 

 

 

 

(standard)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P= Low-iridescence specular

 

 

 

 

 

 

 

 

 

 

W=

White Paint

*Consult factory for availability of louver finishes.

LAMP

QUANTITY:

(By Others)

4=4 Lamp

LAMP/

FIXTURE LENGTH:

32=T88 34=T12 (Nominal 48")

VOLTAGE:

 

 

OPTIONS:

120 or 277

 

Add appropriate suffix

 

 

 

to catalog no., ie: (GLR)

 

BALLAST TYPE:

 

1

& 2 Lamp Mag. T12

LE

 

 

 

 

<20THD <10THD

1

& 2 Lamp Elec. T8

SO*

HI*

1-4 Lamp Elec. T8

O4*

H4*

LOL Dimming T8

PS

*Instant Start Standard

Other dimming options. Consult factory.

OPTIONS & ACCESSORIES

STEM AND CANOPY SETS: Suspends fixture 6", 12", 18" or 24" from surface.

(Four per fixture is recommended.) Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"), ASC24 CSP (24")

FUSING: Internal fast-blow fusing.

SUFFIX: GLR.

Internal slow-blow fusing.

SUFFIX: GMF.

RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture is standard. SUFFIX: RF.

ELECTRICAL/WIRING OPTIONS Consult factory.

SPECIFICATIONS

PERFORMANCE: In an installation of 4 lamp 32W luminaires in a room cavity ratio of 1, with a reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .64. To prevent glare the VCP shall be not less than 88 either lengthwise or cross wise (at 100fc level) and the average brightness at 65° shall not exceed 254 footlamberts. To control veiling reflections, luminaire output in the 30°-90° zone shall be not less than 63%.

SPECIFICATIONS (continued)

MATERIALS: Chassis parts are die-formed 20 gauge cold rolled steel, stud- welded for rigidity with all seams finished smooth.

LOUVER: pre-anodized aluminum (Coilzak® or equal).

STANDARD FINISH: Louver—low iridescence, semi-specularpre-anodized vertical grain reflector sheet. Cavity—white baked acrylic enamel minimum 86% reflectance. Phosphate undercoating. Chassis exterior—white baked acrylic enamel.

ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS: I.B.E.W./UL and C-UL.

Job Information

 

Type:

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902

Page 2
Image 2
Lightolier Options & Accessories, Specifications, SPECIFICATIONS continued, DEEPCELL SURFACE DPB2S32LS432, Photometry