Lighting Systems EC1-1

Page 3 of 3

 

Energos Control System 1-Light T8 per 4' (121.92cm) (Nominal) Louver

 

Ballast Ordering Information

 

 

Lamp Ordering Information

 

Design

Lamp Type

Ballast Factor

Start Type

THD %

Design

Lamp Type

Wattage

Rated Output

Color (K)

(Lumens)

 

 

 

 

 

 

 

 

 

D

T8

0.71

Program

<10

A

T8

28

2725

3000

E

T8

0.88

Program

<10

B

T8

28

2725

3500

H

Dim T8

1.00/.05

Program

<10

C

T8

28

2725

4100

 

 

 

 

 

D

T8

30

2850

3000

 

 

 

 

 

E

T8

30

2850

3500

 

 

 

 

 

F

T8

30

2850

4100

 

 

 

 

 

G

T8

32

3000

3000

 

 

 

 

 

H

T8

32

3000

3500

 

 

 

 

 

I

T8

32

3000

4100

 

 

 

 

 

J

T8

32

3100

3000

 

 

 

 

 

K

T8

32

3100

3500

 

 

 

 

 

L

T8

32

3150

4100

Lamp and Ballast System Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lamp Type

 

Ballast

 

Ballast

 

Lamp Rated

 

Lamp

 

Lamp

 

IES Output

 

System

 

System

 

System

 

Start

 

 

 

 

 

 

 

 

 

 

 

Design

 

 

 

 

Rated

 

Color

 

 

Input

 

Efficacy

 

Lamp Life

 

(T8 or T5)

 

Factor (BF)

 

THD (%)

 

Wattage

 

 

 

(lumens)

 

 

 

 

Type

 

 

 

 

 

Output

 

(Kelvin)

 

 

Watts

 

(lum/watt)

 

(Hours)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DA

T8

 

0.71

 

<10

 

28

 

2725

 

3000

 

2199

 

20.0

 

96.74

 

24000

 

Program

DB

T8

 

0.71

 

<10

 

28

 

2725

 

3500

 

2199

 

20.0

 

96.74

 

24000

 

Program

DC

T8

 

0.71

 

<10

 

28

 

2725

 

4100

 

2199

 

20.0

 

96.74

 

24000

 

Program

DD

T8

 

0.71

 

<10

 

30

 

2850

 

3000

 

2299

 

21.5

 

94.12

 

24000

 

Program

DE

T8

 

0.71

 

<10

 

30

 

2850

 

3500

 

2299

 

21.5

 

94.12

 

24000

 

Program

DF

T8

 

0.71

 

<10

 

30

 

2850

 

4100

 

2299

 

21.5

 

94.12

 

24000

 

Program

DG

T8

 

0.71

 

<10

 

32

 

3000

 

3000

 

2420

 

23.0

 

92.61

 

24000

 

Program

DH

T8

 

0.71

 

<10

 

32

 

3000

 

3500

 

2420

 

23.0

 

92.61

 

24000

 

Program

DI

T8

 

0.71

 

<10

 

32

 

3000

 

4100

 

2420

 

23.0

 

92.61

 

24000

 

Program

DJ

T8

 

0.71

 

<10

 

32

 

3100

 

3000

 

2501

 

23.0

 

95.70

 

30000

 

Program

DK

T8

 

0.71

 

<10

 

32

 

3100

 

3500

 

2501

 

23.0

 

95.70

 

30000

 

Program

DL

T8

 

0.71

 

<10

 

32

 

3150

 

4100

 

2541

 

23.0

 

97.24

 

30000

 

Program

EA

T8

 

0.88

 

<10

 

28

 

2725

 

3000

 

2725

 

25.5

 

94.04

 

24000

 

Program

EB

T8

 

0.88

 

<10

 

28

 

2725

 

3500

 

2725

 

25.5

 

94.04

 

24000

 

Program

EC

T8

 

0.88

 

<10

 

28

 

2725

 

4100

 

2725

 

25.5

 

94.04

 

24000

 

Program

ED

T8

 

0.88

 

<10

 

30

 

2850

 

3000

 

2850

 

27.5

 

91.20

 

24000

 

Program

EE

T8

 

0.88

 

<10

 

30

 

2850

 

3500

 

2850

 

27.5

 

91.20

 

24000

 

Program

EF

T8

 

0.88

 

<10

 

30

 

2850

 

4100

 

2850

 

27.5

 

91.20

 

24000

 

Program

EG

T8

 

0.88

 

<10

 

32

 

3000

 

3000

 

3000

 

29.0

 

91.03

 

24000

 

Program

EH

T8

 

0.88

 

<10

 

32

 

3000

 

3500

 

3000

 

29.0

 

91.03

 

24000

 

Program

EI

T8

 

0.88

 

<10

 

32

 

3000

 

4100

 

3000

 

29.0

 

91.03

 

24000

 

Program

EJ

T8

 

0.88

 

<10

 

32

 

3100

 

3000

 

3100

 

29.0

 

94.07

 

24000

 

Program

EK

T8

 

0.88

 

<10

 

32

 

3100

 

3500

 

3100

 

29.0

 

94.07

 

24000

 

Program

EL

T8

 

0.88

 

<10

 

32

 

3150

 

4100

 

3150

 

29.0

 

95.59

 

24000

 

Program

HG

T8 DIM

 

1.0 / 0.5

 

<10

 

32

 

2850

 

3000

 

2850 / 143

 

34 / 8

 

83.80

 

NA

 

Program

HH

T8 DIM

 

1.0 / 0.5

 

<10

 

32

 

2850

 

3500

 

2850 / 143

 

34 / 8

 

83.80

 

NA

 

Program

HI

T8 DIM

 

1.0 / 0.5

 

<10

 

32

 

2850

 

4100

 

2850 / 143

 

34 / 8

 

83.80

 

NA

 

Program

*25°C Rating

All data is per 1 lamp on a two lamp system at 277 VAC. Data is based on Osram Sylvania specifications.

When ordering no lamps provided by Lightolier, use lamp code “Z”.

Do not alter lumen values or ballast factor light losses when completing calculations using Energos IES files. Files have already been adjusted. The lumen value for the lamp (within a Lighting Design program) will be the IES Ouput value shown on this table.

The lamp life table demonstrates the effects of shortened cycle-times with both program start and instant start ballasts. The graph shows that instant ballasts are susceptible to shortened lamp life if short cycle periods of less than 3 hours are used. For cycle periods of greater than 3 hours program start ballast are not required.

Lamp Life Table using program start and instant start ballasts.

Job Information

Type:

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 Philips Group • C0808

Page 3
Image 3
Lightolier EC1-1 specifications Lamp Ordering Information, Wattage

EC1-1 specifications

The Lightolier EC1-1 is a state-of-the-art architectural luminaire designed to meet the diverse lighting needs of commercial and residential spaces. Its sleek design and advanced features make it an ideal choice for any modern environment.

One of the key features of the EC1-1 is its energy efficiency. Utilizing LED technology, the luminaire provides high-quality illumination while consuming significantly less energy compared to traditional lighting solutions. This not only reduces electricity costs but also minimizes the environmental impact, making it a sustainable choice for eco-conscious consumers.

The EC1-1 is available in various color temperatures, allowing users to select the perfect ambiance for their space. Whether it’s a warm light for a cozy atmosphere or a cooler tone for a more vibrant look, the flexibility in color options ensures that the EC1-1 can adapt to any setting.

Furthermore, this luminaire boasts excellent light output and uniformity, thanks to its advanced optical design. The light distribution is carefully engineered to eliminate dark spots while providing a comfortable visual experience. This is particularly beneficial in commercial settings such as offices, retail spaces, and hospitality environments, where productive and inviting lighting is essential.

The Lightolier EC1-1 is also designed for easy installation and maintenance. Its compact size and lightweight construction facilitate a straightforward mounting process, making it suitable for both new projects and retrofitting existing installations. The durable construction ensures longevity, reducing the frequency of replacements and associated costs.

Another standout characteristic of the EC1-1 is its versatility. It can be used in various applications, including general lighting, accent lighting, and task lighting, making it suitable for a wide range of settings such as schools, galleries, and healthcare facilities. Its minimalist aesthetics blend seamlessly with different interior styles, from contemporary to traditional.

Additionally, the EC1-1 supports various control options, including dimming capabilities and smart lighting integrations. This allows users to tailor their lighting experience further and enhances energy savings. With the Lightolier EC1-1, achieving sophisticated lighting control has never been easier.

In summary, the Lightolier EC1-1 is a multifaceted luminaire that stands out for its energy efficiency, excellent light quality, and versatility. Its innovative technologies and design make it a reliable choice for anyone looking to elevate their lighting in both personal and professional spaces.