Lightolier instruction sheet IS FAEM3, C0506, Read And Follow All Safety Instructions

Models: FAEM3

1 4
Download 4 pages 19.69 Kb
Page 1
Image 1
INSTRUCTION SHEET NO.

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE

This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To assure full compliance with local codes and regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.

Retain these instructions for maintenance reference.

INSTRUCTION SHEET NO.

IS:FAEM3

C0506

Page 1 of 4

Installation of Compact Fluorescent Emergency Ballast Accessory FAEM3E to Standard Calculite Four-Pin Electronic Compact Fluorescent Lamp Frame-In Kit

IMPORTANT SAFEGUARDS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD BE FOLLOWED INCLUDING THE FOLLOWING:

1.TURN OFF AC POWER BEFORE PROCEEDING.

2.DO NOT INSTALL INSULATION WITHIN 3 INCHES OF FIXTURE SIDES OR WIRING COMPARTMENT, NOR ABOVE FIX- TURE IN SUCH A MANNER AS TO ENTRAP HEAT.

3.BE SURE ALL ELECTRICAL CONNECTIONS ARE COMPLETE AND THE JUNCTION BOX IS CLOSED BEFORE INVERTER CONNECTORS (LOCATED IN THE SWITCH/INDICATOR LIGHT BOX) ARE CONNECTED.

4.DO NOT USE OUTDOORS.

5.DO NOT LET POWER SUPPLY CORDS TOUCH HOT SURFACES.

6.DO NOT MOUNT NEAR GAS OR ELECTRICAL HEATERS.

7.USE CAUTION WHEN SERVICING BATTERIES. CONTAINS NICKEL-CADMIUM RECHARGEABLE BATTERY. MUST BE RECYCLED OR DISPOSED OF PROPERLY. DO NOT SHORT CIRCUIT; MAY CAUSE BURNS.

8.EQUIPMENT SHOULD BE MOUNTED IN LOCATIONS AND AT A HEIGHT WHERE IT WILL NOT READILY BE SUBJECT TO TAMPERING BY UNAUTHORIZED PERSONNEL.

9.THE USE OF ACCESSORY EQUIPMENT NOT RECOMMENDED BY THE MANUFACTURER MAY CAUSE AN UNSAFE CONDITION.

10.DO NOT USE THIS EQUIPMENT FOR OTHER THAN INTENDED USE.

11.THIS UNIT HAS MORE THAN ONE POWER SUPPLY CONNECTION POINT. TO REDUCE THE RISK OF ELECTRICAL SHOCK, DISCONNECT BOTH NORMAL AND EMERGENCY POWER SUPPLIES BEFORE SERVICING.

12.BEFORE SERVICING TO PREVENT ELECTRICAL SHOCK, DISCONNECT THE INVERTER CONNECTORS OF THE EMER- GENCY BATTERY PACK (LOCATED IN THE SWITCH/INDICATOR LIGHT BOX). MAKE CERTAIN THAT THE SWITCHED (IF THE FIXTURE IS SWITCHED) AND THE UNSWITCHED LINE TO THE EMERGENCY BATTERY PACK ARE TURNED OFF AT THE FUSE BOX. SERVICING SHOULD BE PERFORMED BY QUALIFIED SERVICE PERSONNEL ONLY.

13.BEFORE ANY INSTALLATION, MAKE SURE TO CHECK THE COMPATIBILITY MATRIX BELOW BEFORE INSTALLATION. INCORRECT MATCHING MAY CAUSE ELECTRICAL SHOCK AND DAMAGE TO BALLASTS AND LAMPS. FOR USE WITH NON-DIMMING (U SERIES) AND DIMMING (J-SERIES) FRAME-IN KITS.

Emergency Ballast

Lamp

Wattage

Compatible Ballast

 

 

13W

 

 

Quad Tube 4-Pin

18W

Electroninc Non-Dimming

 

 

Advance Mark 7 and Mark 10 (Dimming)

FA-EM3E

26W

 

 

Lutron compact SE, Hi-Lume,

 

18W

 

 

 

 

TU-Wire (Dimming)

 

Triple Tube 4-Pin

26W

 

 

 

32W

 

 

 

 

 

 

42W

 

SAVE THESE INSTRUCTIONS

®

LIGHTOLIER a GENLYTE THOMAS company.
631 Airport Road, Fall River, MA 02720
Page 1
Image 1
Lightolier instruction sheet IS FAEM3, C0506, Read And Follow All Safety Instructions, Airport Road, Fall River, MA