Lightolier GOS2G232 dimensions Ordering Information, Options/Accessories, Specifications continued

Models: GOS2G232

1 2
Download 2 pages 38.43 Kb
Page 2
Image 2
Page 2 of 2

GO2 GOS2G232

Page 2 of 2

Model No. GOS2G232UNVC5

LER = FP - 81.1 IW - 51.22 BF - 0.78 Comparative yearly lighting energy cost per

1000 lumens = $2.96 Report Number: G2008092 Catalog Number: GOS2G232UNVC5 Lamp: (2) F32T8/841 Alto Advantage Luminaire: GO2 2'X4' with 12 cell louver. Ballast: Advance IOP-2P32-LW-SC Report is based on 3100 Lumens per lamp. Efficiency: 85.9%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.7

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

45.960

 

21.960

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

1

95

91

88

86

83

81

82

80

79

2

87

81

76

76

72

69

73

70

67

3

80

72

66

68

63

59

66

62

58

4

74

64

57

61

55

51

59

54

50

5

68

58

51

55

49

45

53

48

44

6

63

52

45

50

44

39

49

43

39

7

58

47

40

46

39

35

44

39

35

8

54

43

36

42

36

31

41

35

31

9

51

40

33

38

32

28

37

32

28

10

48

37

30

35

30

26

35

29

25

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

2123.

3376.

3487.

55

1812.

2612.

1721.

65

1413.

1297.

857.

75

1091.

1103.

991.

85

898.

881.

828.

2' x 4' Recessed Fluorescent, High Performance Louver Static or Air Supply/Return, 2 Lamp T8

CANDELA DISTRIBUTION

 

0.0

45.0

90.0

FLUX

0

1780

1780

1780

 

5

1785

1798

1822

173

15

1686

1966

2263

559

25

1507

2148

2505

952

35

1275

1990

2228

1169

45

978

1550

1606

1117

55

677

976

643

753

65

389

357

236

358

75

184

186

167

190

85

51

50

47

56

90

7

7

5

 

 

 

 

 

TYPICAL V.C.P.'s

 

 

 

 

 

 

 

 

Mounting Height

 

9' Ceiling

50 Footcandles

Room

 

 

 

 

Size

North

East

South

West

30x30

81

82

87

86

40x40

77

80

82

87

60x30

83

77

90

83

60x60

73

75

80

84

100x100

72

73

77

78

 

 

ZONAL LUMEN SUMMARY

 

 

 

 

ZONE

LUMENS % LAMP

% FIXT

00-030

1685

 

27.2

31.6

00-040

2854

 

46.0

53.6

00-060

4724

 

76.2

88.7

00-090

5329

 

85.9

100.0

90-180

0000

 

0.0

000.0

00-180

5329

 

85.9

100.0

Ordering Information

Explanation of Catalog Number. Example: GOS2G232UNVC5

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GO2 Series

 

 

 

 

 

 

 

 

 

 

 

Body

Style:

 

 

Fixture

Ceiling

Type:

 

 

 

 

 

 

 

A=Air Supply

 

 

Width

G= Grid

 

 

 

 

 

 

 

S=Static

 

 

 

 

(lay-in T bar)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T= Slot grid or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

two-directional

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

concealed T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(see options)

 

GO

Standard GO2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GC

 

For NYC Code – I.B.E.W. Manufactured

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GN

For NYC Code – Local 3 Manufactured

 

 

 

 

 

 

 

 

 

 

5½" Deep Body

 

 

 

 

 

 

 

Options/Accessories

 

 

 

 

 

 

 

Plaster Frame: Catalog Number: PF24.

 

 

 

 

 

 

 

Radio Interference Filter: To order one RIF per fixture;

SUFFIX: R.

 

 

 

 

 

 

 

 

To order one RIF per ballast;

SUFFIX: B.

 

 

 

 

Fusing: Internal fast-blow fusing. SUFFIX A. Internal slow-blow fusing. SUFFIX C.

Electrical Wiring Options: Consult

factory.

 

 

 

 

 

 

 

Air Closure Strip: SUFFIX: ACS4 (factory installed).

Drywall Kit: Order Catalog Number: FK92X4. (Request Folio OA30-10 Rev. A).

Chicago Plenum: SUFFIX: C.

 

 

 

 

 

 

 

 

 

 

 

 

-

 

 

 

 

2

 

32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lamp

 

 

 

 

 

 

 

 

 

 

 

 

Options:

Quantity

 

 

 

 

 

 

 

 

 

 

 

Add appropriate

 

 

 

 

 

 

Voltage:

 

 

 

suffix to catalog no.,

 

 

 

 

 

 

120, 277 or

 

 

 

 

ie: (C)

 

 

 

 

 

 

UNV=120-277

 

 

 

 

 

 

 

 

 

 

Lamp

Type/

 

 

 

Ballast Type:

Ballast

 

 

Fixture Length:

 

 

 

 

 

<10THD

 

 

 

32= 4' T8

 

 

 

 

 

Factor

 

 

(Nominal 48")

1-2 Lamp Elec. T8

 

HI*

.88

 

 

 

 

 

 

 

 

Advance Optanium

 

C5*

.77

 

 

 

 

 

 

 

 

BI Level Step Dimming

 

V2

 

 

 

 

 

 

 

 

 

 

LOL Dimming

 

PS

 

 

 

 

*Instant Start Standard

Specifications (continued)

Materials: Chassis parts are die-formed code gauge cold rolled steel. Side rails hemmed over and housing ends turned-in for safe handling. Reflector is 94% reflective aluminum.

Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel. Rust preven- tative undercoating. Louver–94% reflective flat white powder coat.

Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

Labels: I.B.E.W. UL and ULc Listed.

This product may have a mercury containing lamp.

Manage in accord with Disposal Laws. See: www.lamprecycle.org

Specifications

Performance: In an installation of 2 lamp 32W luminaries in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .91. To prevent glare the VCP shall be not less than 72 either lengthwise or crosswise and the average brightness at 65° shall not exceed 1413 candelas per square meter. To control veiling reflec- tions, luminaire output in the 30°-90° zone shall not be less than 68.4%.

Air Handling (GOA only) side air passages for air supply or air return. Optional side closure strips. Air return is also provided through the lamp compartment through fixture body ends.

Job Information Type:

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

www.lightolier.com © 2008 a Philips Group

Section 1/Folio A10-10

Lightolier is a Philips group brand

Page 2
Image 2