| INSTRUCTION SHEET NO. |
| ||||
| READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE |
| ||||||
|
|
|
|
|
| |||
| This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To |
|
| IS:4X4 LC |
|
| ||
| assure full compliance with local codes and regulations, check with your local electrical inspector before |
|
|
|
| |||
| installation. To prevent electric shock, turn off electricity at fuse box before proceeding. |
|
|
|
| |||
| Retain these instructions for maintenance reference. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| A0602 |
| Page 2 of 2 |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
B. ADJUST FIK
Set FIK so that bottom edge is flush to, or recessed 1/8” above finished ceiling (Fig. 8).
Final vertical adjustment may be made by means of ADJUSTMENT SCREWS on inside of FIK.
C.
ADJUSTMENT | ADJUSTABLE |
SCREWS | MOUNTING |
| BRACKET |
FIK |
|
FLUSH TO CEILING OR |
|
UP TO 1/8” RECESSED |
|
| FINISHED |
| CEILING |
| FIG. 8 |
FIG. 9
Base of FIK is provided with a
hole pattern (Fig. 9) to assist with the alignment of multiple FIK’s. This hole pattern will facilitate the use of laser beams, plumb lines, etc.
D.INSTALLATION OF REFLECTOR TRIM FOR STANDARD AND CHICAGO PLENUM UNITS
1.Squeeze both TORSION SPRINGS and insert ends into
EMBOSSED SLOTS.
2.Push REFLECTOR TRIM up into FIK until flange is seated firmly against ceiling surface.
**Care and Maintenance of “Alzak” REFLECTOR TRIM finish:**
If handling of REFLECTOR TRIM with anodized or Alzak finish is required, the use of clean white or plastic film gloves is recommended to avoid fingerprints.
Anodized or Alzak surfaces can be cleaned by the following methods:
1.Wipe off with a soft, clean, dry,
2.Wipe off with a soft clean cloth dampened in mild detergent solution. Rinse, then wipe dry with
3.Wipe off with a clean cloth dampened with a solution of wetting agent and water (such as 2 oz. Per gallon “Pluronic
4.Use a liquid wax such as Glass Wax. Avoid gritty cleaning agents.
TORSION |
SPRING |
EMBOSSED |
SLOT |
REFLECTOR |
TRIM |
FIG. 10
E.
1.Turn off power
2.Pull REFLECTOR TRIM down until ends of TORSION SPRINGS reach EMBOSSED SLOTS.
3.Squeeze TORSION SPRINGS to disengage from EMBOSSED SLOTS, and remove REFLECTOR TRIM.
4.Replace lamp (Do not exceed maximum wattage marking).
5.Replace REFLECTOR TRIM.
F. BALLAST REPLACEMENT
1.Make sure AC power is OFF at
2.Remove reflector trim & lamp(s) (See E.).
3.Undo wingnut(s) and remove upper reflector.
4.Remove ballast access plate from housing.
5.Remove screws that secure ballast to junction box cover, pull Ballast through opening into fixture.
6.Disconnect wire leads from ballast
7.Remove ballast from mounting plate, and install new ballast.
8.Insert wire leads into ballast. Follow wiring diagram on
BALLAST. 90°
9.Reattach ballast access plate, upper reflector, lamp(s), and reflector trim.
NUTS | BALLAST | HOUSING |
PLATE | ||
WINGNUT |
| UPPER |
| REFLECTOR | |
|
| |
|
| A |
RELEASE
SLOT
FIG. 11
BALLAST |
FIG. 12
COMPANY
631 Airport Road, Fall River, MA 02720