Lightolier IS:4X4LC Page 2 of, Company, IS 4X4 LC, Airport Road, Fall River, MA, A0602

Models: IS:4X4LC

1 2
Download 2 pages 11.84 Kb
Page 2
Image 2
INSTRUCTION SHEET NO.

 

 

 

 

 

 

 

 

 

 

 

 

INSTRUCTION SHEET NO.

 

 

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE

 

 

 

 

 

 

 

 

This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To

 

 

IS:4X4 LC

 

 

 

assure full compliance with local codes and regulations, check with your local electrical inspector before

 

 

 

 

 

installation. To prevent electric shock, turn off electricity at fuse box before proceeding.

 

 

 

 

 

Retain these instructions for maintenance reference.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A0602

 

Page 2 of 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B. ADJUST FIK

Set FIK so that bottom edge is flush to, or recessed 1/8” above finished ceiling (Fig. 8).

Final vertical adjustment may be made by means of ADJUSTMENT SCREWS on inside of FIK.

C. CLOSE-IN

Close-in and finish ceiling as required.

ADJUSTMENT

ADJUSTABLE

SCREWS

MOUNTING

 

BRACKET

FIK

 

FLUSH TO CEILING OR

 

UP TO 1/8” RECESSED

 

 

FINISHED

 

CEILING

 

FIG. 8

FIG. 9

Base of FIK is provided with a

hole pattern (Fig. 9) to assist with the alignment of multiple FIK’s. This hole pattern will facilitate the use of laser beams, plumb lines, etc.

D.INSTALLATION OF REFLECTOR TRIM FOR STANDARD AND CHICAGO PLENUM UNITS

1.Squeeze both TORSION SPRINGS and insert ends into

EMBOSSED SLOTS.

2.Push REFLECTOR TRIM up into FIK until flange is seated firmly against ceiling surface.

**Care and Maintenance of “Alzak” REFLECTOR TRIM finish:**

If handling of REFLECTOR TRIM with anodized or Alzak finish is required, the use of clean white or plastic film gloves is recommended to avoid fingerprints.

Anodized or Alzak surfaces can be cleaned by the following methods:

1.Wipe off with a soft, clean, dry, lint-free cloth.

2.Wipe off with a soft clean cloth dampened in mild detergent solution. Rinse, then wipe dry with lint-free cloth or paper towel.

3.Wipe off with a clean cloth dampened with a solution of wetting agent and water (such as 2 oz. Per gallon “Pluronic L62-LF” by Wyandotte Products). Wipe dry.

4.Use a liquid wax such as Glass Wax. Avoid gritty cleaning agents.

TORSION

SPRING

EMBOSSED

SLOT

REFLECTOR

TRIM

FIG. 10

E. RE-LAMPING

1.Turn off power

2.Pull REFLECTOR TRIM down until ends of TORSION SPRINGS reach EMBOSSED SLOTS.

3.Squeeze TORSION SPRINGS to disengage from EMBOSSED SLOTS, and remove REFLECTOR TRIM.

4.Replace lamp (Do not exceed maximum wattage marking).

5.Replace REFLECTOR TRIM.

F. BALLAST REPLACEMENT

1.Make sure AC power is OFF at fuse-box.

2.Remove reflector trim & lamp(s) (See E.).

3.Undo wingnut(s) and remove upper reflector.

4.Remove ballast access plate from housing.

5.Remove screws that secure ballast to junction box cover, pull Ballast through opening into fixture.

6.Disconnect wire leads from ballast push-in terminals. (Insert pin or paper clip in RELEASE SLOT, Fig. 11)

7.Remove ballast from mounting plate, and install new ballast.

8.Insert wire leads into ballast. Follow wiring diagram on

BALLAST. 90°

9.Reattach ballast access plate, upper reflector, lamp(s), and reflector trim.

NUTS

BALLAST

HOUSING

PLATE

WINGNUT

 

UPPER

 

REFLECTOR

 

 

 

 

A

RELEASE

SLOT

FIG. 11

BALLAST

FIG. 12

COMPANY

631 Airport Road, Fall River, MA 02720

Page 2
Image 2
Lightolier IS:4X4LC Page 2 of, Company, IS 4X4 LC, Airport Road, Fall River, MA, Instruction Sheet No, A0602