INSTRUCTION SHEET NO. |
| READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING LUMINAIRE | |||
|
|
| |||
IS: C3MR |
|
| This luminaire is intended for installation in accordance with the National Electrical Code and local regulations. | ||
|
| To assure full compliance with local codes and regulations, check with your local electrical inspector before | |||
|
|
|
|
| installation. To prevent electric shock, turn off electricity at fuse box before proceeding. |
|
|
|
|
| Retain these instructions for maintenance reference. |
|
|
|
| ||
B0206 |
| Page 2 of 2 |
| ||
|
|
|
INSTALLATION PROCEDURE FOR CALCULITE→ EVOLUTION TRIMS
8. Install TRIM FACEPLATE by compressing TORSION SPRING
into corresponding detail of TRIM BODY then pushing TRIM Fig. 1 FACEPLATE up flush to ceiling. Fig’s 4 & 5
TRIM MAINTENANCE
RELAMPING - Make sure that power to luminaire is OFF. To relamp, simply swing TRIM FACEPLATE down allowing TORSION SPRING to hold in place. Pull down on LAMP REMOVAL SPRING. Disconnect LAMP from LAMP SPRINGS and SOCKET. Install new LAMP following steps 4, 5, and 6 above.
CARE OF ALZAK REFLECTOR- Wipe with a soft, clean, dry,
Securing Clips in the disengaged position
Trim Body Flush or slightly recessed
Fig. 2
Fig. 3
Insert Trim Body
Engage Clip
| Fig. 4 |
| Fig. 5 |
|
|
|
|
|
|
|
|
|
|
|
|
U.S. AND FOREIGN PATENTS PENDING
A COMPANY
631 Airport Road, Fall River, MA 02720