Lighting Systems LP-17
1BHFPG
Performance
CANDLEPOWER CURVE |
|
| CANDLEPOWER |
| ||
| ZONE 0 | 22 | 45 | 67 | 90 | |
| DEG. |
| CANDELAS |
|
| |
|
|
|
|
| ||
| 180 | 1138 | 1138 | 1138 | 1138 | 1138 |
| 175 | 1135 | 1132 | 1136 | 1138 | 1135 |
| 165 | 1099 | 1109 | 1125 | 1141 | 1142 |
| 155 | 1029 | 1052 | 1080 | 1084 | 1086 |
| 145 | 905 | 944 | 959 | 965 | 967 |
| 135 | 743 | 777 | 783 | 802 | 804 |
| 125 | 611 | 620 | 638 | 682 | 661 |
| 115 | 424 | 421 | 470 | 539 | 557 |
| 105 | 242 | 245 | 299 | 293 | 289 |
| 95 | 54 | 82 | 82 | 91 | 96 |
| 90 | 14 | 25 | 47 | 65 | 74 |
| 85 | 29 | 42 | 66 | 89 | 99 |
| 75 | 87 | 103 | 137 | 162 | 173 |
| 65 | 162 | 186 | 225 | 239 | 236 |
| 55 | 288 | 318 | 372 | 405 | 405 |
| 45 | 427 | 476 | 574 | 587 | 609 |
| 35 | 610 | 661 | 739 | 830 | 866 |
REPORT NO: LRL | 25 | 770 | 813 | 866 | 945 | 977 |
CAT NO: LP2D3T84U | 15 | 887 | 920 | 952 | 990 | 994 |
LAMPS: 3 F32T8 | 5 | 964 | 972 | 986 | 993 | 995 |
LUMENS: 2900 | 0 | 977 | 977 | 977 | 977 | 977 |
EFFICIENCY: 68.5% |
|
|
|
|
|
|
COEFFICIENTS OF UTILIZATION
%EFFECTIVE CEILING CAVITY REFLECTANCE
|
|
|
| 80 |
|
| 70 |
|
| 50 |
|
|
|
|
|
| WALL REFLECTANCE |
|
|
| |||||
|
|
| 70 | 50 | 30 | 70 | 50 | 30 | 50 | 30 | 10 |
|
|
| 0 | 72 | 72 | 72 | 65 | 65 | 65 | 53 | 53 | 53 |
|
RATIO | 66 | 63 | 60 | 60 | 57 | 55 | 47 | 45 | 44 |
| ||
1 |
| |||||||||||
2 | 60 | 56 | 52 | 55 | 51 | 47 | 42 | 40 | 38 |
| ||
3 | 55 | 49 | 45 | 50 | 45 | 41 | 38 | 35 | 32 |
| ||
CAVITY | 51 | 44 | 39 | 46 | 40 | 36 | 34 | 30 | 28 |
| ||
4 |
| |||||||||||
5 | 47 | 39 | 34 | 43 | 36 | 32 | 30 | 27 | 24 |
| ||
6 | 43 | 35 | 30 | 39 | 33 | 28 | 27 | 24 | 21 |
| ||
ROOM | 40 | 32 | 27 | 36 | 30 | 25 | 25 | 21 | 19 |
| ||
7 |
| |||||||||||
8 | 37 | 29 | 24 | 34 | 27 | 22 | 23 | 19 | 17 |
| ||
9 | 34 | 26 | 21 | 31 | 24 | 20 | 21 | 17 | 15 |
| ||
10 | 32 | 24 | 19 | 29 | 22 | 18 | 18 | 15 | 13 |
| ||
|
|
| 20% FLOOR CAVITY REFLECTANCE |
|
| |||||||
DISTRIBUTION |
|
|
|
|
|
|
| |||||
Zone |
| Lumens |
| % Lamp | % Luminaire | |||||||
| 2397 |
|
| 27.6 |
|
| 40.2 |
|
| |||
3562 |
|
| 40.9 |
|
| 59.8 |
|
| ||||
5959 |
|
| 68.5 |
|
| 100.0 |
|
|
Fixture Lengths & Mounting Locations
|
|
|
|
|
|
| 48” (121.92cm) |
|
|
|
|
|
|
|
|
|
|
| 96” (243.84cm) |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
4’ |
|
|
|
|
|
|
|
|
|
|
| 8’ |
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
| 4’ 2” (127.00cm) |
|
|
|
|
|
|
|
|
|
|
| 8’ 2” (248.92cm) |
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
96” (243.84cm)
48” (121.92cm)
12’
12’ 2” (370.84cm)
96” (243.84cm) 96” (243.84cm)
16’
16’ 2” (492.76cm)
1 |
|
| 1 |
1 | 1 |
| 2 |
12
3
End Set
1
1
1
1
1
1
Cable/ Joiner
1
1
2
2
96” (243.84cm) | 96” (243.84cm) | 48” (121.92cm) | |
20’ | 20’ 2” (614.68cm) |
| |
|
| ||
96” (243.84cm) | 96” (243.84cm) | 96” (243.84cm) | |
24’ | 24’ 2” (736.60cm) |
| |
|
| ||
Mounting Accessories |
|
| |
Cable/Joiner Assembly | Power Feed End Set | Ceiling Grid Kit | |
Standard Cable Length is 36” (91.44cm) | Standard Cable Length is 36” (91.44cm) | ||
CGK | |||
Single Cable: LP2C36 | Straight Cord: LP2EC36 | ||
Includes both Standard 1” (2.54cm) | |||
Single Cable & Cord: LP2CC36 | 4 Wire Cord*: LP2EC36X4 | ||
Tee Bar Clip & Slot Tee Clip | |||
Single Cable & 4 Wire Cord: LP2CC36X4 | * use for dimming and/or |
| |
| emergency battery packs |
|
Job Information | Type: |
"JSQPSU3PBE'BMM3JWFS."t t'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #