Lightolier MDS2G36PS4FT Page 2 of, Photometry, Ordering Information, Options/Accessories, Type

Models: MDS2G36PS4FT

1 2
Download 2 pages 50.84 Kb
Page 2
Image 2
Page 2 of 2

MD*4™ 2'x2' Recessed Fluorescent MDS2G36PS4FT

Page 2 of 2

Examination Light, 1-1/2" Deep, 36 Cell (6 Rows) Parabolic Louver, Static, 4 Lamp TT5

Photometry

Model No. MDS2G36PS4FT120SB

G93062

DATE: 05-10-1993

MDS2G36PS4FT120SB

 

4GE F40BX/SBX35/RS, EACH RATED 3150 LUMENS 2X2 TROF 4 LAMP TT5

LER = FP - 51.3

IW - 132

BF - 0.96

 

 

 

 

 

 

Comparative yearly lighting energy cost per 1000 lumens = $4.67

 

 

 

coefficients of utilization — zonal cavity method

 

 

 

 

 

 

 

RC

 

 

80

 

 

50

 

 

30

 

 

RW

 

70

50

30

50

30

10

50

30

10

 

1

 

63

61

59

57

56

55

55

54

54

 

2

 

59

56

53

53

51

49

51

49

48

ratio

3

 

55

51

47

48

46

44

47

45

43

4

 

51

46

42

44

41

39

43

40

38

 

 

cavity

5

 

48

42

38

40

37

34

39

38

34

6

 

44

38

34

37

33

31

36

33

31

room

7

 

41

35

31

34

30

27

33

30

27

8

 

38

31

27

30

27

24

30

26

24

 

9

 

35

28

24

27

24

21

27

24

21

 

10

 

33

26

22

25

21

19

25

21

19

INITIAL FOOTCANDLE READINGS ON BED

 

 

 

 

 

 

 

 

 

 

 

1 FIXTURE

 

 

 

2 FIXTURES

 

 

 

 

 

 

C

 

 

 

 

 

 

 

C

 

 

 

 

 

L

 

 

 

 

 

L

 

 

 

 

 

1"

1"

 

1"

1"

 

 

 

 

 

 

 

 

 

 

WALL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

106

111

107

 

6"

 

52.5

54.8

 

52.7

 

 

 

 

 

 

 

 

119

125

120

 

 

 

1"

 

63.9

66.8

 

64.1

 

 

 

 

 

128

134

129

 

 

 

 

 

 

 

 

 

 

 

 

74.5

78.0

 

74.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

133

139

133

 

 

 

 

 

77.9

81.6

 

78.1

 

 

 

 

 

 

 

 

132

138

133

 

 

 

 

 

75.6

79.1

 

75.8

 

 

 

 

 

 

 

 

123

129

123

 

 

 

 

 

68.6

71.8

 

68.8

 

 

 

 

 

 

 

 

109

114

110

 

 

 

 

 

57.6

60.3

 

57.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ordering Information

Explanation of Catalog Number. Example: MDS2G36PS4FT120SBR

MD

S

2

36

4

FT

 

 

 

 

 

 

 

 

 

Blank: = Standard

 

 

 

Body Style:

Fixture

N = NYC Code

 

 

 

S = Static

Width

 

 

 

 

 

 

 

 

 

 

 

MD*4

 

 

 

 

2'x2' Recessed

 

 

 

 

Examination

 

 

 

 

Light

 

 

*Consult factory for availability of louver finishes.

Options/Accessories

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Options:

 

 

 

Number of

 

Lamp

Lamp Fixture

Voltage:

 

 

Add appropriate

 

 

 

Cells

 

 

Quantity

 

Length:

120 or 277

 

 

 

 

 

 

 

 

 

 

suffix to catalog

 

 

 

 

 

 

 

 

 

FT = Twin Tube

 

 

 

 

 

 

 

 

 

 

 

Louver:

 

T5

 

 

 

 

 

 

 

no, ie: (R)

 

Ceiling Type:

 

 

 

 

 

 

 

 

G = Grid (lay-in)

PS = Low Iridescence

(Nominal 24")

 

 

 

Ballast:

 

 

T-bar

Specular (standard)

 

 

 

 

 

 

 

 

 

<20THD

<10THD

F =

Flanged (over lap)

With Prismatic

 

 

 

 

2-2 Lamp Elec. (TT5)

 

SB*

IB*

 

Z spline and plaster

Overlay

 

 

 

 

 

 

(40 Watt)

 

 

 

 

frame

LS = Low Iridescence

 

 

 

 

LOL TT5 Dimming)

 

PB

 

T =

Slot grid or

Semi-Specular

 

 

 

 

 

 

 

 

 

 

*Instant Start Standard

 

 

 

 

two-directional

(standard)

With

 

 

 

 

 

 

 

 

concealed

Prismatic Overlay

 

 

 

 

Other dimming options. Consult factory.

T (see options)

Specifications (continued)

Fusing: Internal fast-blow fusing. Suffix: GLR. Internal slow-blow fusing. Suffix: GMF.

Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz. One per fixture. Suffix:

R. One per ballast. Suffix: B.

Electrical Wiring Options: Consult factory.

Drywall/Plaster: For drywall or plaster ceiling, Order Catalog Number: FK92X2

(see Folio OA 30-10) or Catalog Number: S2X2 F Kit (See Folio OA30-30).

Specifications

Louver: PS = low iridescence specular pre-anodized aluminum (standard).

LS = low iridescence semi-specular pre-anodized aluminum. Note: both louver selections come with a virgin acrylic overlay to enclose all lamps. VA = .095" nominal thickness prismatic virgin acrylic.

Electrical: Instant start HPF, SB (Biax Type) thermally protected class "P" electronic ballast UL-listed. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

Labels: I.B.E.W./UL and ULc Listed.

Performance: In an installation of 4 lamps 40 W luminaires in a room cavity of 1, with reflectance of 80% ceiling, 50% walls, 20% floor, the C.U. shall not be less than .61. To reduce glare the VCP shall be not less than 87 either length- wise or crosswise (at 100 fc level) and the average brightness at 65° shall not exceed 403 footlamberts. To prevent veiling reflections, luminaire output in the 30°-90° zone shall be not less than 59.0%.

Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing has all edges turned over for safe handling.

Louver: Pre-anodized aluminum (Coilzak® or equal).

Overlay: Prismatic virgin acrylic, pattern 12.

Finish: Cavity—white baked polyester enamel minimum reflectance 86%. Phosphate undercoating. Chassis exterior—black baked polyester enamel to reduce ballast temperature.

Job Information

Type:

 

 

 

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710

We reserve the right to change details of design, materials and finish.

Copyright 2002 Lightolier

 

Section8/Folio R40-30 REV. A

Page 2
Image 2
Lightolier MDS2G36PS4FT Page 2 of, Photometry, Ordering Information, Options/Accessories, Specifications continued, Type