Lightolier MPA2G36LP32U Page 2 of, Options/Accessories, Specifications, Photometry, Type

Models: MPA2G36LP32U

1 2
Download 2 pages 30.12 Kb
Page 2
Image 2
PARABAFFLE plus MPA2G36LP32U or 17
Section 2/Folio G20-14
LAMP
QUANTITY:
2=2 Lamp
3=3 Lamp

PARABAFFLE plus MPA2G36LP32U or 17

Page 2 of 2

PHOTOMETRY

MPA2C36LP120O3

2'x2' RECESSED FLUORESCENT, 11/2" DEEP, 36 CELL PARABOLIC LOUVER, STATIC OR AIR SUPPLY/RETURN, 2 OR 3 LAMP, T8, 1-5/8"U LAMP OR 2' LAMP

MODEL NO. MPA2G36LP32U

 

Luminaire Efficacy Rating

 

 

LER-50.8

Watts-77.6

BF-0.88

 

coefficients of utilization — zonal cavity method

 

 

 

 

 

 

 

RF

 

20

 

 

20

 

 

20

 

 

 

RC

 

80

 

 

50

 

 

30

 

 

 

RW

70

50

30

50

30

10

50

30

10

 

 

1

61

59

57

56

54

53

54

53

52

 

ratio

2

57

53

50

50

48

46

49

47

45

 

3

53

48

44

45

43

40

44

42

40

 

cavity

4

49

43

39

41

38

35

40

37

35

 

5

45

39

35

37

34

31

36

33

31

 

room

6

42

35

31

34

30

28

33

30

27

 

7

39

32

28

31

27

25

30

27

25

 

 

 

 

8

36

30

25

29

25

22

28

25

22

 

 

9

34

27

23

26

23

20

26

23

20

 

 

10

32

25

21

25

21

19

24

21

18

visual comfort probability (VCP) average 100 fc; reflectances 80/50/20

room size

 

 

 

 

ceiling height

 

 

 

 

ceiling height

 

W

L

 

8.5

10.0

13.0

16.0

 

 

8.5

10.0

13.0

16.0

20

20

 

 

77

70

62

67

 

 

77

69

62

65

20

30

 

 

79

73

67

62

 

 

79

72

66

62

20

40

 

 

82

76

71

65

 

 

81

75

70

65

20

60

 

 

83

78

73

69

 

 

83

77

72

68

30

20

 

 

81

75

65

66

 

 

81

74

65

65

30

30

 

 

83

77

69

61

 

 

83

76

68

62

30

40

 

 

85

79

72

65

 

 

85

78

71

65

30

60

 

 

86

81

75

68

 

 

86

80

74

68

30

80

 

lengthwise

87

82

77

71

 

crosswise

87

82

76

70

40

20

 

83

77

69

68

 

82

77

69

66

40

30

 

85

80

73

63

 

84

79

72

63

40

40

 

86

81

75

67

 

86

81

75

66

40

60

 

luminaries

87

83

77

69

 

luminaries

87

82

77

69

40

80

 

88

84

79

72

 

88

84

79

71

40

100

 

88

85

81

74

 

88

84

80

73

60

30

 

85

81

75

67

 

85

80

74

67

 

 

 

 

60

40

 

 

87

82

77

70

 

 

87

82

77

69

60

60

 

 

88

84

79

72

 

 

88

83

79

71

 

 

60

80

 

 

88

85

81

74

 

 

88

85

80

74

60

100

 

 

89

86

82

76

 

 

89

85

82

75

100

40

 

 

87

82

79

71

 

 

87

82

78

71

100

60

 

 

88

84

81

74

 

 

88

84

80

73

100

80

 

 

88

85

82

76

 

 

89

85

82

76

100

100

 

 

89

86

83

78

 

 

89

85

83

77

ORDERING INFORMATION

Explanation of Catalog Number. Example: MPA2G36LP32U120O3RF

 

MP

 

 

 

 

 

 

2

 

 

 

 

 

36

 

 

 

 

 

 

 

 

 

 

BODY

 

STYLE:

 

 

CEILING

 

TYPE:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOUVER

 

 

 

 

 

 

A=Air Supply

 

 

G= Grid

 

 

 

FINISH*:

 

 

 

 

 

 

S=Static

 

 

 

(lay-in T bar)

 

 

L= Low

 

 

 

 

 

 

 

 

 

 

 

 

 

F=Flanged

 

 

 

Iridescence

 

 

PARABAFFLE

 

 

 

 

FIXTURE

(overlap)

NUMBER OF

 

Semi-specular

P=Dual “V”

1-1/2" PARABOLIC:

 

 

 

 

WIDTH

Z spline and

CELLS

 

(standard)

Reflector

 

Pre-anodized

 

 

 

 

 

 

plaster frame

 

 

P= Low

(3 Lamp)

aluminum louver

 

 

 

 

 

 

T=Slot grid or

 

 

 

Iridescence

S=Single “V”

 

 

 

 

 

 

 

 

 

 

 

two-directional

 

 

 

Specular

Reflector

 

 

 

 

 

 

 

 

 

 

 

concealed T

 

 

W=White Baked

(2 Lamp)

 

 

 

 

 

 

 

 

 

 

 

(see options)

 

 

 

Enamel

 

 

LAMP TYPE/

FIXTURE LENGTH:

2U=T8, 1-5/8"U Lamp

17=T8, 2' Lamp

(Nominal 48")

 

 

 

 

 

 

 

 

VOLTAGE:

 

 

 

 

 

 

 

 

OPTIONS:

120 or 277

 

 

Add appropriate

 

 

 

 

suffix to catalog

 

 

 

 

no, ie: (RF)

BALLAST TYPE:

<10THD

 

 

<20THD

1 & 2 Lamp Elec. T8

 

SO*

 

HI*

1-3 Lamp Elec. T8

 

O3*

 

H3*

LOL T8 Dimming

 

PS

 

*Instant Start Standard

Other dimming options. Consult factory.

OPTIONS/ACCESSORIES

PLASTER FRAME: Catalog Number: PF22.

CONTINUOUS ROW INSTALLATION: For F type

fixtures, half-width flanges are required between fixtures. Order Catalog Number: S2FCTRIM (each joint).

SPLAY TRIM: For T ceiling type only.

SUFFIX: CTZ22 S2 SPLAY TRIM.

SPECIFICATIONS:

PERFORMANCE: In an installation of 3 lamp 31W luminaires in a room cavity ratio of 1, with reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .59. To prevent glare the VCP shall be not less than 71 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 1338 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 62.7%.

AIR HANDLING (MPA only) side air passages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provided through the lamp compartment through fixture body ends.

MATERIALS: Chassis parts are die-formed code gauge cold rolled steel. Housing is ribbed for rigidity with side rails hemmed over and housing ends turned-in for safe handling. Louver is pre-anodized

aluminum (Coilzak® or equal).

FINISH: Chassis exterior–black baked polyester enamel. Cavity– white baked poly-

RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture standard. SUF-

FIX: RF.

ELECTRICAL/WIRING OPTIONS: Consult factory.

AIR CLOSURE STRIP: SUFFIX: ACS2 (factory installed).

DRYWALL KIT: Order Catalog Number: FK92X2. (Request Folio OA30-10)

CHICAGO PLENUM: SUFFIX: CP.

ester enamel minimum 86% reflectance. Phosphate undercoating. Louver–low irides- cence semi-specular anodized vertical grain aluminum reflector sheet is standard. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS: I.B.E.W. UL and ULc Listed.

Job Information

 

Type:

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902

Page 2
Image 2
Lightolier Page 2 of, Options/Accessories, Specifications, PARABAFFLE plus MPA2G36LP32U or, Photometry, Job Information