SLB Surface Box 2' x 4' Fluorescent SLB2SFSVA432
Page 2 of 2 | Flat Steel or Regressed Aluminum Frame, 2, 3, or 4 Lamp T8 or T12 |
Photometry
Model No. SLB2SFSVA432120O4
SLB2SFSVA432120O4
coefficients of utilization — zonal cavity method
| RF |
| 20 |
|
| 20 |
|
| 20 |
| |
| RC |
| 80 |
|
| 50 |
|
| 30 |
| |
| RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 | |
| 1 | 74 | 71 | 69 | 67 | 65 | 64 | 64 | 63 | 62 | |
ratio | 2 | 68 | 64 | 60 | 60 | 57 | 55 | 58 | 56 | 53 | |
3 | 63 | 57 | 52 | 54 | 51 | 47 | 52 | 49 | 47 | ||
| |||||||||||
cavity | 4 | 58 | 51 | 46 | 49 | 45 | 41 | 47 | 44 | 41 | |
5 | 54 | 46 | 40 | 44 | 39 | 36 | 43 | 39 | 35 | ||
room | 6 | 50 | 41 | 36 | 40 | 35 | 32 | 39 | 34 | 31 | |
7 | 46 | 37 | 32 | 36 | 31 | 28 | 35 | 31 | 27 | ||
| 8 | 42 | 34 | 30 | 32 | 28 | 24 | 32 | 27 | 24 | |
| 9 | 39 | 30 | 25 | 29 | 24 | 21 | 28 | 24 | 21 | |
| 10 | 36 | 28 | 22 | 26 | 22 | 19 | 26 | 22 | 19 |
Ordering Information
Explanation of Catalog Number. Example: SLB2SFSVA432120O4
SL
B
2
S
VA
SLB Surface: | Body Style: | Fixture | Ceiling Type: |
|
|
|
|
|
|
| Lamp | Lamp/Fixture | Voltage: |
|
|
|
| Options: |
Lens Frame | Surface Box | Width | S = Surface |
|
|
|
|
|
| Quantity: | Length: | 120 or 277 |
|
|
| Add appropriate | ||
Surface |
|
|
| Lens |
| Lens | 2 = 2 Lamp | 32 = T8 |
|
|
|
|
| suffix to catalog | ||||
Fluorescent |
|
|
| Frame: | Shielding Type: | 3 = 3 Lamp | 34 = T12 |
|
|
|
|
| no, ie: (GLR) | |||||
|
|
| Ballast Type: | |||||||||||||||
|
|
| FS = Flush full- | VA = Pattern 12 | 4 = 4 Lamp | (Nominal 48") |
|
| ||||||||||
|
|
|
| size steel |
| lens, .095" |
|
| 1 & 2 Lamp Mag. T12 LE |
| ||||||||
|
|
|
| frame |
| nominal pris- |
|
|
|
| <20THD <10THD | |||||||
|
|
| RA = Regressed |
| matic lens |
|
| 1 & 2 Lamp Elec. T8 | SO* | HI* | ||||||||
|
|
|
| flush full- |
| (standard). |
|
| O3* | H3* | ||||||||
|
|
|
| size |
| see options |
|
| O4* | H4* | ||||||||
|
|
|
| aluminum |
| and consult |
|
| ||||||||||
|
|
|
|
|
|
| LOL Dimming T8 | PS* |
| |||||||||
|
|
|
| frame |
| factory. |
|
|
| |||||||||
|
|
|
|
|
|
| *Instant Start Standard |
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Options & Accessories
Other dimming options. Consult factory.
Fusing: Internal
Internal
Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz. One per fixture.
Suffix: R. One per ballast, Suffix: B.
Stem and Canopy Sets: Suspends fixture 6", 12" 18" or 24" from surface. (Four
per fixture is recommended. Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"), ASC24 CSP (24").
Specifications
Performance: In an installation of 4 lamp 32W luminaires in a room cavity ratio of 1, with a reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .60. To prevent glare the average brightness at 65° shall not exceed 2457 candelas per square meter. To control veiling reflections, luminaire output in the
Materials: Chassis parts are
Finish: White baked polyester powder coat.
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and
Job Information |
| Type: |
|
|
|
Lightolier a Genlyte Thomas Company | www.lightolier.com |
Technical Information: (978)
631 Airport Road, Fall River, MA 02720 • (508)