Lightolier SLB2SFSVA432 Page 2 of, Photometry, Ordering Information, Options & Accessories, Type

Models: SLB2SFSVA432

1 2
Download 2 pages 399 b
Page 2
Image 2
Page 2 of 2
Section 3A/Folio H70-12

SLB Surface Box 2' x 4' Fluorescent SLB2SFSVA432

Page 2 of 2

Flat Steel or Regressed Aluminum Frame, 2, 3, or 4 Lamp T8 or T12

Photometry

Model No. SLB2SFSVA432120O4

SLB2SFSVA432120O4

coefficients of utilization — zonal cavity method

 

RF

 

20

 

 

20

 

 

20

 

 

RC

 

80

 

 

50

 

 

30

 

 

RW

70

50

30

50

30

10

50

30

10

 

1

74

71

69

67

65

64

64

63

62

ratio

2

68

64

60

60

57

55

58

56

53

3

63

57

52

54

51

47

52

49

47

 

cavity

4

58

51

46

49

45

41

47

44

41

5

54

46

40

44

39

36

43

39

35

room

6

50

41

36

40

35

32

39

34

31

7

46

37

32

36

31

28

35

31

27

 

8

42

34

30

32

28

24

32

27

24

 

9

39

30

25

29

24

21

28

24

21

 

10

36

28

22

26

22

19

26

22

19

Ordering Information

Explanation of Catalog Number. Example: SLB2SFSVA432120O4

SL

B

2

S

VA

SLB Surface:

Body Style:

Fixture

Ceiling Type:

 

 

 

 

 

 

 

Lamp

Lamp/Fixture

Voltage:

 

 

 

 

Options:

Lens Frame

Surface Box

Width

S = Surface

 

 

 

 

 

 

Quantity:

Length:

120 or 277

 

 

 

Add appropriate

Surface

 

 

 

Lens

 

Lens

2 = 2 Lamp

32 = T8

 

 

 

 

 

suffix to catalog

Fluorescent

 

 

 

Frame:

Shielding Type:

3 = 3 Lamp

34 = T12

 

 

 

 

 

no, ie: (GLR)

 

 

 

Ballast Type:

 

 

 

FS = Flush full-

VA = Pattern 12

4 = 4 Lamp

(Nominal 48")

 

 

 

 

 

 

size steel

 

lens, .095"

 

 

1 & 2 Lamp Mag. T12 LE

 

 

 

 

 

frame

 

nominal pris-

 

 

 

 

<20THD <10THD

 

 

 

RA = Regressed

 

matic lens

 

 

1 & 2 Lamp Elec. T8

SO*

HI*

 

 

 

 

flush full-

 

(standard).

 

 

1-3 Lamp Elec. T8

O3*

H3*

 

 

 

 

size

 

see options

 

 

1-4 Lamp Elec. T8

O4*

H4*

 

 

 

 

aluminum

 

and consult

 

 

 

 

 

 

 

 

 

LOL Dimming T8

PS*

 

 

 

 

 

frame

 

factory.

 

 

 

 

 

 

 

 

 

 

*Instant Start Standard

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Options & Accessories

Other dimming options. Consult factory.

Fusing: Internal fast-blow fusing. Suffix: GLR.

Internal slow-blow fusing. Suffix: GMF.

Electrical/Wiring Options: Consult factory.

Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz. One per fixture.

Suffix: R. One per ballast, Suffix: B.

Stem and Canopy Sets: Suspends fixture 6", 12" 18" or 24" from surface. (Four

per fixture is recommended. Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"), ASC24 CSP (24").

Specifications

Performance: In an installation of 4 lamp 32W luminaires in a room cavity ratio of 1, with a reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .60. To prevent glare the average brightness at 65° shall not exceed 2457 candelas per square meter. To control veiling reflections, luminaire output in the 30–90° zone shall be not less than 68%.

Materials: Chassis parts are die-formed 20 gauge cold rolled steel.

Finish: White baked polyester powder coat.

Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

Labels: I.B.E.W./UL and C-UL.

Job Information

 

Type:

 

 

 

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. Copyright 2002 Lightolier

Page 2
Image 2
Lightolier SLB2SFSVA432 Page 2 of, Photometry, Ordering Information, Options & Accessories, Specifications, Job Information